Command Dictionary | Set Zhold Behavior |
|
|
Set Zhold Behavior
Tools Supported: FastScan
Scope: All modes
Usage
SET ZHold Behavior OFf ON
Description
Specifies whether ZHOLD gates retain their state values.
The ZHOLD gate allows FastScan to model
By invocation default, FastScan assumes the retained value is always the clock off_state value for both the good machine and the faulty machine simulation.
FastScan cannot assume a state from a previous scan pattern or from a load operation. The amount of time the ZHOLD gate can hold its value is limited to the number of sequential clock cycles.
Arguments
∙OFf
A literal that specifies not to allow ZHOLD gates to retain values.
∙ON
A literal that specifies for FastScan to use ZHOLD gates to retain values subject to restrictions that the rules checker identified. This is the default behavior upon invocation of FastScan.