Command Dictionary

Report Random Weights

 

 

Report Random Weights

Tools Supported: FastScan

Scope: Atpg, Fault, and Good modes

Usage

REPort RAndom Weights

Description

Displays the current random pattern weighting factors for all primary inputs in the random weight list.

The Report Random Weights command displays the current random weight value placed on primary inputs using the Add Random Weights command. You can specify the default weighting factor for all primary inputs by using the Set Random Weights command but, FastScan does not place the default value in the random weight list.

You use this command primarily when simulating Built-In Self Test (BIST) circuitry.

Examples

The following example displays the weighting factors for all the primary inputs in the random weight list:

set system mode fault

add random weights 100 indata2 add random weights 25 indata4 report random weights

set random patterns 612 insert testability

Related Commands

 

Add Random Weights

Set Random Weights

Delete Random Weights

 

FastScan and FlexTest Reference Manual, V8.6_4

2-363

Page 391
Image 391