Command Dictionary | Report Random Weights |
|
|
Report Random Weights
Tools Supported: FastScan
Scope: Atpg, Fault, and Good modes
Usage
REPort RAndom Weights
Description
Displays the current random pattern weighting factors for all primary inputs in the random weight list.
The Report Random Weights command displays the current random weight value placed on primary inputs using the Add Random Weights command. You can specify the default weighting factor for all primary inputs by using the Set Random Weights command but, FastScan does not place the default value in the random weight list.
You use this command primarily when simulating
Examples
The following example displays the weighting factors for all the primary inputs in the random weight list:
set system mode fault
add random weights 100 indata2 add random weights 25 indata4 report random weights
set random patterns 612 insert testability
Related Commands |
|
Add Random Weights | Set Random Weights |
Delete Random Weights |
|
FastScan and FlexTest Reference Manual, V8.6_4 |