Analyze Drc Violation

Command Dictionary

 

 

With this example, the schematic viewer displays the sequential element associated with the clk input, along with a backward trace through the gates and nets to the associated primary input.

add clocks 0 clk

set system mode atpg

//. . .

//---------------------------------------------------------

//Begin scan clock rules checking.

//---------------------------------------------------------

//1 scan clock/set/reset lines have been identified.

//All scan clocks successfully passed off-state check.

//Error: Clock /CLK cannot capture data with other clocks off. (C2-1)

open schematic viewer analyze drc violation c2-1

Related Commands

 

Open Schematic Viewer

Set Drc Handling

Report Drc Rules

Set Schematic Display

2-136