Command Dictionary | Set Gate Report |
|
|
Set Gate Report
Tools Supported: DFTInsight, FastScan, and FlexTest
Scope: All modes
Usage
For FastScan
SET GAte REport {Normal Trace Error_pattern Fault_status Bist_data TIe_value Constrain_value Seq_depth_data Clock_cone pin_name {Drc_pattern procedure_name
For FlexTest
SET GAte REport {Normal Race Trace Error_pattern TIe_value Constrain_value Clock_cone pin_name Analysis [Control Observe] {Drc_pattern procedure_name
DFTInsight Menu Path:
Setup > Reporting Detail
Description
Specifies the additional display information for the Report Gates command.
The Set Gate Report command controls the type of additional information that the Report Gates command displays. Each Set Gate Report option causes the Report Gates command to provide different details regarding the gates on which it reports. This command also controls the information displayed for each instance in the DFTInsight Schematic View area.
When you exit the Setup system mode, the trace and any
For information on the format output by the different options in this command, refer to the Report Gates reference page.
FastScan and FlexTest Reference Manual, V8.6_4 |