Timing Command Dictionary SET END_MEASURE_CYCLE TIME
FastScan and FlexTest Reference Manual, V8.6_4 A-7
The design.g1 test procedure file contains the following shift procedure for scan
group g1:
PROC SHIFT =
FORCE_SCI 0;
MEASURE_SCO 0; // must happen at time 0
FORCE clk_a 1 300;
FORCE clk_a 0 400;
PERIOD 500;
END;
Related Commands
SET SINGLE_CYCLE TIME