Command Dictionary | Set Output Comparison |
|
|
Set Output Comparison
Tools Supported: FlexTest
Scope: All modes
Usage
SET OUtput Comparison OFf {ON
Description
Specifies whether FlexTest performs a good circuit simulation comparison.
The Set Output Comparison command allows you to specify for FlexTest to compare good circuit simulation results to an external test pattern set. The purpose is to verify the correctness of the simulation model.
The
Arguments
∙OFf
A literal that prevents FlexTest from performing a comparison of the outputs. This is the default upon invocation of FlexTest.
∙ON
A literal that specifies for FlexTest to compare the good circuit simulation results.
∙-X_ignore None
A switch that specifies FlexTest to compare x values between the simulated results and the reference output.
∙-X_ignore Reference
A switch that specifies FlexTest to ignore the comparison between x values in the reference output. This is the default.
FastScan and FlexTest Reference Manual, V8.6_4 |