Command Dictionary

Setup Checkpoint

 

 

-Nopattern (FlexTest Only)

An optional switch that specifies that the tool should not save the test set. This option is provided in cases where you only want to save the fault list and not the test pattern set (use this option in conjunction with the -Faultlistfault_file option).

period

An optional integer that specifies the number of minutes between each write of the test patterns. The default is 100 minutes.

-Replace

An optional switch that forces the tool to overwrite the file if a file by that name already exists.

-Overwrite

An optional switch that specifies to overwrite the test patterns each time there are any differences. This is the default.

-Sequence

An optional switch that writes the new test patterns to a new file each time a test pattern differs. The first file that the tool writes to is filename; each subsequent file is named “ filenameN”, where N is an integer that starts at 1 and increases by one for each additional file.

-Ascii (FastScan Only)

An optional switch that allows the pattern files to be saved in ascii format. This is the default format.

-Binary(FastScan Only)

An optional switch that allows the pattern files to be saved in binary format.

-Faultlist fault_file

An optional switch that allows the fault list to be saved.

-Keep_aborted(FastScan Only)

An optional switch that identifies aborted faults as they are written to the fault_file. This is useful in cases where aborted faults need to be restored later

FastScan and FlexTest Reference Manual, V8.6_4

2-605