Command Dictionary | Set Gate Report |
|
|
The format of the fault status data is as following:
where
DS — Detected by simulation
DI — Detected by implication
PU — Possible detect untestable
PT — Possible detect testable
AU — Atpg untestable
UC — Undetected uncontrolled.
UO — Undetected unobserved.
UU— Untestable unused. BL — Untestable blocked. TI — Untestable tied.
RE — Untestable redundant.
The Report Display Instances command will report the fault detection status in DFTInsight message window.
∙Bist_data (FastScan Only)
A literal that specifies for the Report Gates command to display previously calculated control and observe values. To set the Bist_data option, you must do so prior to rules checking and you must
∙TIe_value
A literal that specifies for the Report Gates command to display the simulated values that result from all natural tied gates and learned constant value non- scan cells.
FastScan and FlexTest Reference Manual, V8.6_4 |