Add Control Points | Command Dictionary |
|
|
And — A literal specifying that FastScan perform an AND of the cell output pins and random values.
Or — A literal specifying that FastScan perform an OR of the cell output pins and random values.
∙
An optional switch specifying for the tool to assume that a single point controls the pin_pathnames.
Examples
The following example adds a control point to the cell output pin, I_1006/O, to analyze its controllability effects:
set system mode atpg analyze control report control data
add control points I_1006/O analyze control
report control data
Related Commands |
|
Analyze Control | Report Control Data |
Delete Control Points | Report Control Points |
FastScan and FlexTest Reference Manual, V8.6_4 |