Report Display Instances

Command Dictionary

 

 

The next two commands show the differences between the high-level and the detailed reports:

report display instances i_2_16

// /I_2_16/DFF0 (58) DFF

report display instances i_2_16 -full

// /I_2_16/DFF0 (58) DFF

// SET I (0) 51-

// RESET I (1) 47-

// CLK I (X) 17-

// DATA I (X) 20-

// “OUT” O (X) 15- 16-

Related Commands

 

Add Display Instances

Report Gates

Analyze Drc Violation

Set Gate Report

Open Schematic Viewer

 

2-284

FastScan and FlexTest Reference Manual, V8.6_4