Command Dictionary Delete Capture Handling
FastScan and FlexTest Reference Manual, V8.6_4 2-161
-All
A switch that removes all special data capture handling.
-SInk
An optional switch specifying that the object argument is a termination point.
This is the default behavior for the command.
If you use this switch in combination with the -All switch, FastScan removes
all special data capture handling on all the sink elements.
-SOurce
An optional switch specifying that the object argument is an origination point
for data capture.
If you use this switch in combination with the -All switch, FastScan removes
all special data capture handling on all the source elements.
Examples
The following example changes the data capture handling of two specific gates
and then removes one of those changes.
add capture handling new 1158 1485 -source
delete capture handling 1158
Related Commands
Add Capture Handling Report Capture Handling