Command Dictionary

Set Iddq Strobe

 

 

For FastScan — A switch that restricts IDDQ detection to those patterns which have the IDDQ measure statement.

For FastScan — A switch that restricts IDDQ measures to those test cycles which have the IDDQ measure statement.

-All

For FastScan — A switch that allows FastScan to use all patterns for IDDQ fault detection.

For FlexTest — A switch that allows FlexTest to use all test cycles for IDDQ fault detection.

Examples

The following example fault grades an external IDDQ pattern file and restricts IDDQ detection/measures to those patterns/test cycles which have the IDDQ measure statement:

set system mode fault

set pattern source external pat_file set fault type iddq

set iddq strobe -label add faults -all

run

Related Commands

 

Select Iddq Patterns

Set Iddq Checks

Set Fault Type

Set Pattern Source

FastScan and FlexTest Reference Manual, V8.6_4

2-507