Command Dictionary | Set Iddq Strobe |
|
|
For FastScan — A switch that restricts IDDQ detection to those patterns which have the IDDQ measure statement.
For FastScan — A switch that restricts IDDQ measures to those test cycles which have the IDDQ measure statement.
∙-All
For FastScan — A switch that allows FastScan to use all patterns for IDDQ fault detection.
For FlexTest — A switch that allows FlexTest to use all test cycles for IDDQ fault detection.
Examples
The following example fault grades an external IDDQ pattern file and restricts IDDQ detection/measures to those patterns/test cycles which have the IDDQ measure statement:
set system mode fault
set pattern source external pat_file set fault type iddq
set iddq strobe
run
Related Commands |
|
Select Iddq Patterns | Set Iddq Checks |
Set Fault Type | Set Pattern Source |