Command Dictionary

Report Gates

 

 

The following describes the fields for the read port message line:

Identifies the gate index number of the first data output line for a given read port. In the list of gate inputs, the other address inputs will immediately follow.

Identifies the gate index number of the first address line for a given read port. In the list of gate inputs, the other address inputs will immediately follow.

read port: read=G/G (vvv-v-v) first_adr=G first_do=G stability=vv

Identifies the behavior of the read clock and read enable lines for a given write port:

Identifies the following stability behavior for a given read port, respectively:

read control stability read load stability

The values can be either of the following:

S(stable) U (unstable)

G/G

Two gate index numbers separated by a “/”.

 

First G is the read clock line.

 

Second G is the read enable line. A “-”means there is no enable line.

(vvv-v-v) Up to five values indicating the behavior of the following conditions, respectively:

clock_off_enable_off

clock_on_enable_off (Not shown if there is no enable line.) clock_off_enable_on (Not shown if there is no enable line.) two optional clock information values separated by dashes (-)

The first three values can be any of the following:

X(read X)

0 (read 0)

1 (read 1)

H (hold old values) P (potential read)

The last two values can be either of the following:

CLK (read clock connected to scan clock)

IH (read clock line is inactive high)

FastScan and FlexTest Reference Manual, V8.6_4

2-317

Page 345
Image 345
Mentor v8.6_4 manual 317