Command Dictionary | Set Multiple Load |
|
|
Set Multiple Load
Tools supported: Fastscan
Scope: All modes
Usage
SET MUltiple Load ON OFf
Description
Specifies how the tool handles multiple scan loads.
The Set Multiple Load command specifies how the tool handles multiple scan loads. It supports patterns containing more than one scan load operation. You can use this command to take advantage of
When multiple load patterns are in the pattern set, an additional line is output in the statistics report. This extra line indicates the number of multiple load patterns in the current pattern set. For example:
Statistics report
| #faults | #faults |
fault class | (coll.) | (total) |
FU (full) | 150 | 198 |
DS (det_simulation) | 71 | 105 |
DI (det_implication) | 65 | 79 |
PT (posdet_testable) | 14 | 14 |
test_coverage | 95.33% | 96.46% |
fault_coverage | 95.33% | 96.46% |
atpg_effectiveness | 95.33% | 96.46% |
#test_patterns | 18 |
#clock_sequential_patterns | 3 |
#multiple_load_patterns | 15 |
#simulated_patterns | 64 |
CPU_time (secs) | 0.3 |
FastScan and FlexTest Reference Manual, V8.6_4 |