FastScan and FlexTest Reference Manual, V8.6_4
2-342
Report Nonscan Cells Command Dictionary
-TIE0
An optional switch that displays the non-scan cells which are always 0 after
each loading and before the next unloading.
Non-scan cells that the tool models as TIE0 indicate that the pin constraints
hold the cell’s value during non-scan operation.
-TIE1
An optional switch that displays the non-scan cells which are always 1 after
each loading and before the next unloading.
Non-scan cells that the tool models as TIE1 indicate that the pin constraints
hold the cell’s value during non-scan operation.
-TIEX (FastScan Only)
An optional switch that displays the non-scan cells which are always unknown
(X) after each loading and before the next unloading.
-TLatch (FastScan Only)
An optional switch that displays the non-scan cells which FastScan models as
transparent latches.
-Clock_sequential (FastScan Only)
An optional switch that displays all clock_sequential cells that are valid when
the sequential depth is set to non-zero.
-INIT0 (FastScan Only)
An optional switch that displays a list of cells which DRC has identified as
being initialized to 0 by scan load but has failed to prove that it is tied to 0.
Non-scan cells that the tool models as INIT0 indicate one of the following:
oThe test procedure can set the memory element to 0 after scan loading.
oThe non-off clock is a reset.
-INIT1 (FastScan Only)
An optional switch that displays a list of cells which DRC has identified as
being initialized to 1 by scan load but has failed to prove that it is tied to 1.