Mentor v8.6_4 manual Report Nonscan Cells, ∙ -INITXFlexTest Only

Models: v8.6_4

1 831
Download 831 pages 41.57 Kb
Page 369
Image 369

Command Dictionary

Report Nonscan Cells

 

 

Report Nonscan Cells

Tools Supported: FastScan and FlexTest

Scope: Atpg, Fault, and Good modes

Usage

For FastScan

REPort NOnscan Cells [-All -TIE0 -TIE1 -TIEX -TLatch -Clock_sequential -INIT0 -INIT1]

For FlexTest

REPort NOnscan Cells [-All -INITX -TIE0 -TIE1 -Hold -Data_capture]

Description

Displays the non-scan cells whose model type you specify.

The Report Nonscan Cells command displays the instance name, gate number, and model type of the non-scan cells that you specify. The tool assigns a model type to the non-scan cells during the Design Rules Check (DRC) in order to model non-scan memory behavior more exactly.

During scan loading, scan clocks can affect non-scan memory elements. The worst case is to assume that all non-scan memory elements will have an unknown state right after scan loading, which makes some faults difficult to test. Therefore, the tool assigns an appropriate model type to the non-scan cells, which sets them to known values. The argument descriptions that follow describe the conditions that the tool uses to make the various model type assignments.

Arguments

-All

An optional switch that displays all non-scan cells. This is the default.

-INITX(FlexTest Only)

An optional switch that displays the non-scan cells which FlexTest initializes to X after each loading.

FastScan and FlexTest Reference Manual, V8.6_4

2-341