Command Dictionary Set Workspace Size
FastScan and FlexTest Reference Manual, V8.6_4 2-597
Set Workspace Size
Tools Supported: FastScan
Scope: Atpg, Good, and Fault modes
Usage
SET WOrkspace Size factor
Description
Increases the workspace so that FastScan can try to detect the undetected faults
that were aborted due to workspace constraints.
FastScan creates the workspace during the flattening process that is equal in size
to 40 bytes times the number of primitives in the design. You can increase the
workspace by any positive integer amount and FastScan creates a workspace that
is equal to the default workspace size times the factor that you specify.
Arguments
factor
A required positive integer that specifies the multiplication factor that you
want FastScan to use to increase the workspace.
Examples
The following example doubles the current workspace that FastScan has available
for trying to detect faults:
set workspace size 2
Related Commands
Report Aborted Faults