Usage
SET WOrkspace Size factor
Description
Increases the workspace so that FastScan can try to detect the undetected faults that were aborted due to workspace constraints.
FastScan creates the workspace during the flattening process that is equal in size to 40 bytes times the number of primitives in the design. You can increase the workspace by any positive integer amount and FastScan creates a workspace that is equal to the default workspace size times the factor that you specify.
Arguments
∙factor
A required positive integer that specifies the multiplication factor that you want FastScan to use to increase the workspace.
Examples
The following example doubles the current workspace that FastScan has available for trying to detect faults:
set workspace size 2
Related Commands
Report Aborted Faults