FastScan and FlexTest Reference Manual, V8.6_4
2-518
Set Learn Report Command Dictionary
Set Learn Report
Tools Supported: FastScan and FlexTest
Scope: All modes
Usage
SET LEarn Report [OFf | ON]
Description
Specifies whether the Report Gates command can display the learned behavior for
a specific gate.
The Set Learn Report command specifies whether the Report Gates command
should include the information that the tool collects during the static learning
process. The application automatically performs the static learning process
immediately after it flattens the simulation model, which happens when you leave
the Setup mode or issue the Flatten Model command. The static learning process
provides general information on the design that the tool can then use in speeding
up the ATPG process (such as values that are impossible on other gates if the
selected gate is at a specific value.)
Once you enable access to the static learned information with the Set Learn
Report command, you can specify for the tool to display the learned information
on a selected gate by using the Report Gates command.
While you can also access the learned information with the Report Gates
command by using the -Type option, this method displays the information for all
the gates of the specified gate type. When you enable access with the Set Learn
Report command, the tool automatically displays the learned information with all
command options. Therefore, you can restrict the report to the learned information
on an individual object.
Arguments
OFf
An optional literal that disables access to the learned behavior information.
This is the default.