Command Dictionary Analyze Fault
FastScan and FlexTest Reference Manual, V8.6_4 2-141
1 — A literal that specifies that the tool analyze the pin_pathname for a
“stuck-at-1” fault.
-Observe gate_id#
A switch and integer pair that specifies the observe point for the sensitization
analysis.
gate_id# — An integer that specifies a gate identification number whose
location you want to use as the observe point for the sensitization analysis.
-Time integer (FlexTest Only)
A switch and integer that specifies the pin strobe time for the sensitization
analysis. Pin strobes always occur at the end of a timeframe, and the time value
of a pin strobe is always the timeframe number+1.
-Boundary (FastScan Only)
A switch that specifies to display the boundary faults when analyzing an
ATPG untestable, tied, blocked, or redundant fault.
-Auto (FastScan Only)
A switch that automatically determines how far along the path FastScan can
successfully propagate a transition of a path delay fault.
-Continue
A switch that forces the tool to complete the analysis of faults which have
already been detected by the pattern set. This allows you to inspect the
generated pattern by using the Report Faults command.
If you do not specify this switch and FastScan detects the fault category by
simulation, by implication, or as unused, then FastScan displays a message and
terminates the analysis.
-Display (FastScan Only)
A switch that specifies for FastScan to create a gate list relevant to the faults
generated and, if DFTInsight is invoked, to automatically update the schematic
view with the information.