ADD PRimary Inputs net_pathname...
Description
Adds primary inputs.
The Add Primary Inputs command adds an additional primary input to each specified net. Once added, the tool designates them as user class primary inputs, as opposed to the primary inputs described in the original netlist, which it designates as system class primary inputs. Use the
Arguments
∙net_pathname
A required repeatable string specifying the pathname of the nets to which you want to add primary inputs.
∙
An optional switch that specifies disconnection of the original drivers of the net, making the added primary input the only driver of the net. The design must be flattened prior to using this option with the Flatten Model command.
∙
An optional switch that specifies addition of the primary input to the specified nets in all modules.