Command Dictionary | Delete Tied Signals |
|
|
Delete Tied Signals
Tools Supported: FastScan and FlexTest
Scope: Setup mode
Usage
DELete TIed Signals {floating_object_name...
Description
Removes the assigned (tied) value from the specified floating nets or pins.
The Delete Tied Signals command deletes the tied values assigned with the Add Tied Signals command. You can delete tied values from either user class, system class, or full classes of floating nets or pins. If you do not specify a class, the tool deletes the tied values from the user class of floating nets or pins. You can display a list of any class of tied floating nets or pins by using the Report Tied Signals command.
Whenever you delete tied values from nets or pins, be sure to
Arguments
∙floating_object_name
A repeatable string that specifies the names of the tied floating nets or pins whose tied values you want to delete. You can specify the class of floating nets or pins on which to delete the tied values with the
If you do not specify the
∙-All
A switch that deletes the tied values from all tied floating nets or pins in the class of tied floating nets or pins, which you specify with the