Add Display Loop

Command Dictionary

 

 

Arguments

pin_pathname

A string that specifies the pin_pathname of a feedback path gate. When you specify a gate pin name, DFTInsight displays the complete feedback path in which the gate resides.

feedback_id#

A repeatable integer that specifies the identification number of the feedback path whose gates you want DFTInsight to display.

-All

A switch specifying that DFTInsight display the gates for all of the feedback paths.

Examples

The following example invokes the optional schematic viewing application, leaves the Setup mode (thereby flattening the simulation model and performing the learning process), displays the identification numbers of any learned feedback paths, and then schematically displays one of the feedback paths:

open schematic viewer set system mode atpg report feedback paths

Loop#=0,

feedback_buffer=26, #gates_in_network=5

INV

/I_956__I_582/ (51)

PBUS

/I_956__I_582/N1/ (96)

ZVAL

/I_956__I_582/N1/ (101)

INV

/I_956__I_582/ (106)

TIEX

/I_956__I_582/ (26)

Loop#=1,

feedback_buffer=27, #gates_in_network=5

INV

/I_962__I_582/ (52)

PBUS

/I_962__I_582/N1/ (95)

ZVAL

/I_962__I_582/N1/ (100)

INV

/I_962__I_582/ (105)

TIEX

/I_962__I_582/ (27)

add display loop 1