Report Statistics Command Dictionary
If a pattern type has no patterns, the report does not display the count for that type.
If all patterns are basic patterns, it will not display any count. And it counts
clock_sequential patterns that are also clock_po only as clock_sequential patterns.
Refer to the “FastScan Example” on page 2-378 for a sample FastScan statistics
report.
FlexTest Specifics
The FlexTest statistics report lists the following four groups of information:
Circuit Statistics which consists of total numbers for the following:
oprimary inputs
primary outputs
library model instances
netlist primitive instances
combinational gates
sequential elements
simulation primitives
scan cells
scan sequential elements
osequential instances
defined nonscan instances
nonscan instances identified by the DRC
defined scan instances
scan instances identified by the DRC
identified scan instances
Fault List Statistics which consists of:
oThe number of collapsed and total faults that are currently in each class.
The report does not display fault classes with no members.
oThe percentage of test coverage, fault coverage, and ATPG
effectiveness for both collapsed and total faults