Set Flatten Handling

Command Dictionary

 

 

Set Flatten Handling

Tools Supported: FastScan and FlexTest

Scope: All modes

Usage

SET FLatten Handling rule_id [Error Warning NOTe Ignore] [Verbose Noverbose]

Description

Specifies how the tool globally handles flattening violations.

The Set Flatten Handling command specifies the handling of the messages for net checking, pin checking, and gate checking. You can specify that the violation messages for these checks be either error, warning, note, or ignore. If you do not specify error, warning, note, or ignore, then the tool uses either the handling from the last Set Flatten Handling command or, if you have not changed the handling, the initial invocation setting as specified in the following list of rules.

Each rules violation has an associated occurrence message and summary message. The tool displays the occurrence message only for either error conditions or if you specify the Verbose option for that rule. The tool displays the rule identification number in all rules violation messages.

Arguments

rule_id

A required non-repeatable literal that specifies the identification of the exact flattening rule violations whose message handling you want to change.

The flattening rule violations and their identification literals are divided into the following three groups: net, pin, and gate rules violation IDs.

Following are the net rules:

FN1 — A module net is floating. The default upon invocation is warning.

FN2 — A module net has driver and constant value property. The default upon invocation is warning and its property is not used.

FN3 — An instance net is floating. The default upon invocation is warning.

2-484

FastScan and FlexTest Reference Manual, V8.6_4

Page 512
Image 512
Mentor v8.6_4 manual Set Flatten Handling, ∙ ruleid