Command Dictionary

Setup Tied Signals

 

 

Setup Tied Signals

Tools Supported: FastScan and FlexTest

Scope: Setup mode

Usage

SETup TIed Signals X 1 0 Z

Description

Changes the default value for floating pins and floating nets which do not have assigned values.

The Setup Tied Signals command specifies the default value that the tool ties to all floating nets and floating pins that you do not specify with the Add Tied Signals command. Upon invocation of the tool, if you do not assign a specific value, the tool assumes the default value is unknown (X).

If the model is already flattened and then you use this command, you must delete and recreate the flattened model.

Arguments

X

A literal that ties the floating nets or pins to unknown. This is the default upon invocation of the tool.

0

A literal that ties the floating nets or pins to logic 0 (low to ground).

1

A literal that ties the floating nets or pins to logic 1 (high to voltage source).

Z

A literal that ties the floating nets or pins to high-impedance

FastScan and FlexTest Reference Manual, V8.6_4