Command Dictionary | Set Unused Net |
|
|
Set Unused Net
Tools Supported: FlexTest
Scope: Setup mode
Usage
SET UNused Net
Description
Specifies whether FlexTest removes unused bus and wire nets in the design.
To properly handle bus and wire contention, FlexTest should not remove those unused nets. You can display the current settings of unused nets with the Report Environment command.
Arguments
∙-Bus ON OFf
A switch and literal pair that specifies whether FlexTest removes all unused bus nets in the design. The literal choices for the
ON — A literal that specifies for FlexTest to keep all the unused bus nets in the design. This is the default behavior upon invocation of FlexTest.
OFf — A literal that specifies for FlexTest to remove all the unused bus nets in the design.
∙-Wire OFf ON
A switch and literal pair that specifies whether FlexTest removes all unused wire nets in the design. The literal choices for the
OFf — A literal that specifies for FlexTest to remove all the unused wire nets in the design. This is the default behavior upon invocation of FlexTest.
ON — A literal that specifies for FlexTest to keep all the unused wire nets in the design.
FastScan and FlexTest Reference Manual, V8.6_4 |