Timing Command Dictionary

SET SPLIT_MEASURE_CYCLE TIME

 

 

save pat pat.split.titdl -titdl counter.flx.time.split

//Timing file “counter.flx.time.split” commands set time scale 1 ns;

set split_measure_cycle time 250; set force time 300 400;

set measure time 200 350; set cycle time 500;

set procedure file "g1" "counter.ti.g1.split";

//Test procedure file “counter.ti.g1.split”

proc shift =

 

 

measure_sco

 

0;

force_sci

 

0;

force CLK

1

50;

force CLK

0

150;

period

 

250;

end;

 

 

proc load_unload

=

 

force SE

1

0;

force CLEAR

1

150;

force CLK

0

150;

apply shift

10

250;

period

 

250;

end;

 