Timing Command Dictionary SET SPLIT_MEASURE_CYCLE TIME
FastScan and FlexTest Reference Manual, V8.6_4 A-59
save pat pat.split.titdl -titdl counter.flx.time.split
//Timing file “counter.flx.time.split” commands
set time scale 1 ns;
set split_measure_cycle time 250;
set force time 300 400;
set measure time 200 350;
set cycle time 500;
set procedure file "g1" "counter.ti.g1.split";
//Test procedure file “counter.ti.g1.split”
proc shift =
measure_sco 0;
force_sci 0;
force CLK 1 50;
force CLK 0 150;
period 250;
end;
proc load_unload =
force SE 1 0;
force CLEAR 1 150;
force CLK 0 150;
apply shift 10 250;
period 250;
end;
Related Commands
SET SINGLE_CYCLE TIME SET SPLIT_BIDI_CYCLE TIME