Command Dictionary | Set Capture Limit |
|
|
Set Capture Limit
Tools Supported: FlexTest
Scope: All modes
Usage
SET CApture Limit OFf {test_cycle_limit
Description
Specifies the number of test cycles between two consecutive scan operations.
The Set Capture Limit command allows you to limit the number of test cycles that FlexTest captures between two consecutive scan operations for internal ATPG patterns; the command does not affect external patterns. You may need to use this command with hardware testers that limit the number of test cycles between two consecutive scan operations. FlexTest classifies any undetected faults due to the capture limit as atpg_untestable (AU) faults.
You can use the Report Environment command to display the current capture limit.
Arguments
∙OFf
A literal specifying that there is no limit to the number of test cycles that FlexTest allows between two consecutive scan operations. This is the default behavior of FlexTest upon invocation.
∙test_cycle_limit -Maximum -Exact
A positive integer and optional switch pair that specifies either the maximum or the exact number of test cycles that FlexTest allows between two consecutive scan operations. The switch choices are as follows:
FastScan and FlexTest Reference Manual, V8.6_4 |