FastScan and FlexTest Reference Manual, V8.6_4
A-18
SET SPLIT_MEASURE_CYCLE TIME Timing Command Dictionary
capture_clock_on 650;
capture_clock_off 700;
period 800;
end;
set split_measure_cycle time 200;
set procedure file "g1" "ckt2.tp";
//Test procedure file “ckt2.tp”
procedure test_setup =
//test cycle 1
force clk 0 0;
force clk 1 50;
force clk 0 100;
//test cycle 2
force clk 0 200;
force clk 1 250;
force clk 0 300;
//test cycle 3
force clk 0 400;
force clk 1 450;
force clk 0 500;
//test cycle 4
force clk 0 600;
force clk 1 650;
force clk 0 700;
period 800;
end;
procedure shift =
force_sci 0;
measure_sco 0;
force clk 1 50;
force clk 0 100;
period 200;
end;
procedure load_unload =
force SE 1 0;
force CLK 0 0;
force CLKS 1 0;
period 200;
end;