Report Drc Rules | Command Dictionary |
|
|
T4 — The netlist contains all the gates in the backtrace cone of the clock inputs of the blocked gate. The pin data shows the values the tool simulates for all time periods of the shift procedure.
T5 T6 — The netlist contains all the gates in the backtrace cone of the clock inputs of the blocked gate. The pin data shows the values the tool simulates for all time periods of the shift procedure.
T7 — The netlist contains all the gates in the path between the two failing latches. The pin data shows the values the tool simulates for all time periods of the shift procedure.
T11 — A clock input of the memory element closest to the scan chain input must not be turned on during the shift procedure prior to the time of the force_sci statement.
T16 — When clocks and write control lines are off and pin constraints are set, the gate that connects to the input of a reconvergent pulse generator sink gate (PGS) in the long path must be at the
T17 — Reconvergent pulse generator sink gates cannot be connected to any of the following: primary outputs,
T18 — The maximum traced number of cells in the longest scan chain of a group must equal the entered number of repetitions in the apply shift statement in the load_unload procedure.
T19 — If a scan cell has a SLAVE, then all scan cells must have a SLAVE.
T20 — The number of shifts specified using the Set Number Shifts command must be at least equal to the length of the longest scan chain.
T21
T22
T23
| FastScan and FlexTest Reference Manual, V8.6_4 |