Command Dictionary

Set Observation Point

 

 

Set Observation Point

Tools Supported: FastScan

Scope: All modes

Usage

SET OBservation Point Master SLave SHadow Clockpo

Description

Specifies the observation point for random pattern fault simulation.

The Set Observation Point command specifies whether FastScan observes master latches, slave latches, shadow latches, or clock primary outputs during random pattern fault simulation. If you select Master, Slave, or Shadow, FastScan also observes the primary outputs that do not connect to clock lines. The default behavior upon invocation of FastScan is Master.

Arguments

Master

A literal that specifies observation of master latches and normal primary outputs. This is the default behavior upon invocation of FastScan.

SLave

A literal that specifies observation of slave latches and normal primary outputs.

SHadow

A literal that specifies observation of observable shadow latches and normal primary outputs.

Clockpo

A literal that specifies observation of only primary outputs directly connected to clocks.

FastScan and FlexTest Reference Manual, V8.6_4

2-537

Page 565
Image 565
Mentor v8.6_4 manual Set Observation Point, ∙ Master, ∙ SLave, ∙ SHadow, ∙ Clockpo