Herrmidifier Co 6000 owner manual Maintenance, To remove the cylinder, A B, Extended Shutdown, C D

Page 12
Maintenance

Maintenance

To maintain output, the water level in the cylinder will slowly move upwards, exposing new electrode to the water as the electrodes become coated with minerals. Eventually, all of the usable electrode surfaces will be coated and the cylinder will be full of water. At this point, the output will begin to fall and the red “service" light will come on. The unit will shutdown. This indicates the need to change the cylinder-typically 500-2000 hours of operation, depending on the quality of the fill water supply.

To remove the cylinder

1.Drain cylinder completely using the 'on-off- drain" switch.

2.Turn off power to the unit at the external disconnect. Disconnect electrode power wires (#38 & #39) and cylinder full electrode wire (#29) from the tank. These connections are 1/4' quick connects.

3.Disconnect 1” tube at top of tank.

Figure 11A

Figure 11B

4.Remove tank, clean out drain cup and insert with new tank. Be sure that "o" ring is in place on the cylinder fill/drain neck prior to installation (See Figure 11a). New “o" ring is included with each replacement cylinder.

5.Clean and check both the fill and drain valves while servicing the unit.

6.Check the strainer. If it is dirty or restricting the water-replace it.

7.Install cylinder in unit by pushing downward with a slight twisting motion, while ensuring proper orientation of tank within cabinet.

8.Reconnect electrode power wires #38 and #39, and cylinder full electrode, wire #29. Make sure that all electrical connections are securely tightened.

9.Follow cold start-up instructions on page 10. Monitor amp draw for several cycles.

Extended Shutdown

Always drain cylinder completely if unit will be off for an extended period of time. This will preserve the life of the cylinder.

Figure 11C

Figure 11D

12

Image 12
Contents Installation Operation Service 6000 SeriesElectronic Steam Humidifiers TABLE OF CONTENTS SECTION III INSTALLATION INSTRUCTIONSSECTION V TROUBLESHOOTING GUIDE SECTION VI SUGGESTED SPECIFICATIONSSECTION I WARRANTY Warranty SECTION II UNIT OPERATION Basic Operation Key Features Adjustable SetpointsFaults ConductivityEngineering and Application Allowable Operating ConditionsSECTION III INSTALLATION INSTRUCTIONS Mounting Remove foam packing from top of tankPlumbing Steam Distribution Blower Version 6000-1,2DUCTED VERSION 6000-3,4 Distributor Mounting InstructionsWiring Figure Supply PowerElectrical Characteristics Control Circuit ConnectionsStart-upInstructions SECTION IV OPERATING INSTRUCTIONSChecklist Checklist completed byHumidifier Installer Company Checklist completion dateMaintenance To remove the cylinderFigure 11A Figure 11B Extended ShutdownSECTION V TROUBLESHOOTING GUIDE Circuit Board SettingsStandard Settings High Conductivity SettingsProblem / Symptom See - NON-FAULTACTIVATEDFAULT ACTIVATED PROBLEMS Fill System FaultNon-FaultActivated Problems Problem / SymptomReason - Correction Non-FaultActivated Problems - Cont’d Problem / SymptomReason - Correction Blower Version Wiring Diagram6000-1and Blower Version Exploded View 6000-1and Blower Version Parts List 6000-1and Ducted Version Exploded View 6000-3and Ducted Version Parts List 6000-3and Ducted Version Wiring Diagram 6000-3and SECTION VI SUGGESTED SPECIFICATIONS Suggested Specifications Part I-ScopePart II -Scope Part 3 --Execution