Ducted Version Parts List (6000-3 and 6000-4)

1845

Door Interlock

EST-003

Cylinder Full Interface (Set to “A”)

EST-105A

Toroid Transformer

EST-596

Steam Hose

EST-1001B

Main Circuit Board

EST-1062

Drain Cup

EST-1124

Terminal Strip

EST-1141

Red Lamp

EST-1142

Green Lamp (2)

EST-1143

On Off Drain Switch

EST-1146

KEP Nut, 6-32

EST-1147

KEP Nut, 8-32

EST-1409

Universal Bushing

EST-1512

Transformer 115/230 to 24 VAC

EST-1513

Distribution Louver

EST-1514

Relay, 2 pole, 20 A

EST-1519

Circuit Breaker, 2A

EST-1525

Drain Reservoir

EST-1526

Drain Reservoir Gasket

EST-1527

Bridge Rectifier

EST-1528

Capacitor

EST-1530

Terminal Block

EST-1532

Solenoid Operator w/ground wire

EST-1533

Drain Cup Assembly includes:

EST-1542

Power Wire Assembly

EST-1543

Grommet, Vibration Dampening

EST-207

Clamp

EST-353

Bushing

GT-116

Celcon Compression Nuts

GT-118

Fill Valve

GT-134

Fan Interlock Relay

GT-153

Strainer

GT-202

Steam Cylinder Assembly (Standard 230V Units)

GT-176-1

Low Conductivity Steam Cylinder Assembly (Standard 115V Units) Drain Cup Assembly includes:

Solenoid Operator w/ ground wire

21

Image 21
Contents Installation Operation Service 6000 SeriesElectronic Steam Humidifiers SECTION III INSTALLATION INSTRUCTIONS TABLE OF CONTENTSSECTION V TROUBLESHOOTING GUIDE SECTION VI SUGGESTED SPECIFICATIONSSECTION I WARRANTY Warranty SECTION II UNIT OPERATION Basic Operation Adjustable Setpoints Key FeaturesFaults ConductivityAllowable Operating Conditions Engineering and ApplicationSECTION III INSTALLATION INSTRUCTIONS Mounting Remove foam packing from top of tankPlumbing Blower Version 6000-1,2 Steam DistributionDUCTED VERSION 6000-3,4 Distributor Mounting InstructionsFigure Supply Power WiringElectrical Characteristics Control Circuit ConnectionsSECTION IV OPERATING INSTRUCTIONS Start-upInstructionsChecklist completed by ChecklistHumidifier Installer Company Checklist completion dateTo remove the cylinder MaintenanceFigure 11A Figure 11B Extended ShutdownCircuit Board Settings SECTION V TROUBLESHOOTING GUIDEStandard Settings High Conductivity SettingsSee - NON-FAULTACTIVATED Problem / SymptomFAULT ACTIVATED PROBLEMS Fill System FaultNon-FaultActivated Problems Problem / SymptomReason - Correction Non-FaultActivated Problems - Cont’d Problem / SymptomReason - Correction Blower Version Wiring Diagram6000-1and Blower Version Exploded View 6000-1and Blower Version Parts List 6000-1and Ducted Version Exploded View 6000-3and Ducted Version Parts List 6000-3and Ducted Version Wiring Diagram 6000-3and Suggested Specifications Part I-Scope SECTION VI SUGGESTED SPECIFICATIONSPart II -Scope Part 3 --Execution