Herrmidifier Co 6000 owner manual SECTION I WARRANTY Warranty

Page 3
SECTION I WARRANTY

SECTION I WARRANTY

Warranty

1.Herrmidifier warrants to the buyer or any user during the duration of the Warranty that the humidifier described in this manual will be free from defects of material and workmanship for a period of two (2) years from the date of shipment.

2.For this Warranty to be effective, this humidifier must be installed, operated and maintained in accordance with the

Installation Instructions, Operations and Maintenance Manual(s) supplied with the humidifier.

3.In the event of a defect or malfunction in this product during the Warranty Period, user may contact the Customer Service Department or their Herrmidifier Representative for a Material Return Authorization (MRA) number Items tagged (on the outside of the box) with this number may be returned to the Herrmidifier Factory Repair Department for complete reconditioning without charge to the user for parts or labor. Incidental expenses such as cost of transporting the humidifier to Herrmidifier shall be come by the user. Upon completion of the reconditioning, the humidifier will be returned at no cost to the user. In an effort to keep equipment on line, we may send items out and use the MRA to return alleged defective parts for examination. Credit consideration will be given upon return and confirmation of improper performance. In either case item, returned without an MRA number will not be accepted!

4.Each of the 6000 series of steam generating humidifiers contains a plastic steam generating cylinder which is to be considered a routinely disposable part to be changed at regular maintenance intervals at the user's expense. This steam-generating cylinder is not covered by this Warranty. If, after the flat installation of your 6000 humidifier, you feel the steam- generating cylinder is not operating normally, you should contact the Herrmidifier Company, Inc. with an explanation of the problem. However, in the continuing operation of the humidifier, replacements of this part are your responsibility as part of routine maintenance.

5.This Warranty does not cover field labor for repairs to this humidifier or any special, indirect or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.

6.If, after a reasonable number of attempts to do so, Herrmidifier is unable to remedy any defects or malfunctions in this humidifier, then the user may elect either a replacement of such product or part which may be defective without charge or a refund at the buyer's original purchase price.

7.This Warranty gives you specific legal rights, and you may also have other rights, which vary, from state to state.

NOTE

Water quality plays a vital role in the performance and maintenance requirement of any humidifier. Adjustments to the circuit board may be necessary based on the incoming water quality. See pages: 13-16.

Performance problems associated with water quality are not warranty issues!

3

Image 3
Contents Installation Operation Service 6000 SeriesElectronic Steam Humidifiers SECTION VI SUGGESTED SPECIFICATIONS TABLE OF CONTENTSSECTION III INSTALLATION INSTRUCTIONS SECTION V TROUBLESHOOTING GUIDESECTION I WARRANTY Warranty SECTION II UNIT OPERATION Basic Operation Conductivity Key FeaturesAdjustable Setpoints FaultsAllowable Operating Conditions Engineering and ApplicationSECTION III INSTALLATION INSTRUCTIONS Mounting Remove foam packing from top of tankPlumbing Distributor Mounting Instructions Steam DistributionBlower Version 6000-1,2 DUCTED VERSION 6000-3,4Control Circuit Connections WiringFigure Supply Power Electrical CharacteristicsSECTION IV OPERATING INSTRUCTIONS Start-upInstructionsChecklist completion date ChecklistChecklist completed by Humidifier Installer CompanyExtended Shutdown MaintenanceTo remove the cylinder Figure 11A Figure 11BHigh Conductivity Settings SECTION V TROUBLESHOOTING GUIDECircuit Board Settings Standard SettingsFill System Fault Problem / SymptomSee - NON-FAULTACTIVATED FAULT ACTIVATED PROBLEMSNon-FaultActivated Problems Problem / SymptomReason - Correction Non-FaultActivated Problems - Cont’d Problem / SymptomReason - Correction Blower Version Wiring Diagram6000-1and Blower Version Exploded View 6000-1and Blower Version Parts List 6000-1and Ducted Version Exploded View 6000-3and Ducted Version Parts List 6000-3and Ducted Version Wiring Diagram 6000-3and Part 3 --Execution SECTION VI SUGGESTED SPECIFICATIONSSuggested Specifications Part I-Scope Part II -Scope