INSTALLATION
HAMPTON CAST
FACEPLATE INSTALLATION
NOTE: Do not install Cast Faceplate when unit is installed into a Zero Clearance Unit.
1)Lay the faceplate panels fl at, face down on something soft so they don't scratch.
2)Attach the side fi ller brackets to the left and right sides using 3 screws and washer per side.
NOTE: There are filler brackets specifically for each side. The way to differentiate this is that on the side of the brackets there are 2 mounting holes. The side where there is a 7/16" gap from the top of the bracket to the mounting hole, must face the top.
3)Attach the right and left cast sides to the top using 2 screws per side.
Ensure that the
top and sides are
aligned.
4)Use a measuring tape to ensure that the distance between the left and right side pieces is 28" (711mm).
28"
5)ConnecttheON/OFFswitchwires by taking the black and red wires with the blue female ends thru the hole provided and connecting them to the ON/OFF switch.
6)Connect the fan switch wires by taking the black and red wires with the male ends (in the grey harness) thru the hole provided and connect them with the wire connectors from the fan speed control.
7)Insert wires into the strain relief and install into switch box as- sembly.
8)Place the switch box assembly over the boss on the rear left side piece and secure with one screw.
9)Tuck the wires into the faceplate to keep them away from the insert using the clip provided. Attach the clip to the rear of the faceplate to ensure that the wires do not touch the side of the unit.
Switch Box Assembly
Boss on rear left side
piece.
10)The power cord should be run behind the faceplate panel.
FPI | 17 |