Recoton/Advent U31-NG2, U31-LP2 GAS Connection, High Elevation, Draft Hood Connection

Page 8

INSTALLATION

Conversion Kit from Natural Gas to Propane

Model #402-969 for: U31-NG2 Units

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

GAS CONNECTION

GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

1)Turn the unit off and allow it to cool to room temperature.

2)Unplug or disconnect power source to stove.

3)Remove glass front (see manual).

4)Remove logs and brick panels (if in- stalled).

5)Remove the Grate by removing the screws on each side of the grate.

8)Remove regulator from valve and replace with Propane regulator. See diagram 1.

Diagram 1

9)Pull off the pilot cap to expose the pilot orifi ce.

1)If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry or factory built fi replace.

2)The appliance is provided with an opening on the left hand side of the control com- partment. A 1/2" gas supply pipe must be brought near this inlet hole. (See Diagram 3 on page 11).

Remove the 2 screws holding

the grate in position.

6)Remove the Burner Tray by removing the screws on each side of the tray. Push the tray to the left and lift up.

10) Unscrew the pilot orifi ce with the allen key and replace with the LP pilot orifi ce in the kit.

3)Locate the center point where the vent will pass through the chimney above the appli- ance. Move the appliance into the exact location where it is to be installed. Ensure that the Insert is level.

4)The installer must provide a valve with a plugged tapping, accessible for test gauge connection, immediately upstream of the gas supply connection to the appliance.

HIGH ELEVATION

Remove the 2 screws,

push Burner Tray to the left, and lift off.

7)Remove burner orifi ce with 1/2" wrench and replace with the #52 orifi ce in the Kit.

Burner

Orifi ce

11)Replace Burner Tray and reverse steps 5) to 1).

12)Adjust the burner aeration setting to 1/8" to 3/16" as required for the best fl ame pic- ture.

This unit is approved in Canada for altitude 0 to 2000 ft. with the orifi ce supplied. For 0' - 4500' use the optional fi eld conversion kit (Part #400- 970 for Natural Gas units and Part #400-971 for Propane units). In USA refer to ANSI Z223.1- 1988, Appendix F, for re-sizing orifi ce.

DRAFT HOOD

CONNECTION

1)Attach the vent to the fl ue collar on the detachable draft hood. The fl ue collar of the appliance will fi t inside a standard vent and may be fastened directly to the vent by sheet metal screw. Diagram 1.

2)Before pushing the appliance into position inside the fi replace, align the draft hood with the guides on the insert top and push forward. While pushing the unit back into place keep pulling the draft hood forward until the screw hole in the spill tube aligns

8

FPI U31-2 Gas Fireplace Insert

Image 8
Contents U31 Gas Insert FPI GAS Fireplace Insert Table of Contents Safety Label Requirements MA Code CO DetectorInstallation Installation Checklist Minimum Fireplace DimensionsMaterials Required Clearances to CombustiblesDraft Hood Connection GAS ConnectionHigh Elevation GAS Insert Aeration System VentingGAS Pressure Test Test for Flue SpillageLOG SET Installation Optional Brick PanelPins on Rear Log Support PinCutoutNotch Cutout BracketFaceplate & Trim Installation Flush Front InstallationRear View Trim Assembly Diagram Diagram Rear View Faceplate AssemblyBAY Front Installation BAY LouversFlush Louvers Double Door ScreenSide Hook Wiring DiagramMake sure the glass is centered Full Screen Front Bottom Frame Ensure that Top and sides are Aligned Hampton Cast Faceplate InstallationSwitch Box Assembly Boss on rear left side Piece Hampton Cast Faceplate Grill Installation Slide side fi ller bracketU31 Grill Stop Bracket Side Hook SlotsFaceplate Trim Bracket Firebox Flange Excalibur Surround InstallationFlanges Blanking Plate Faceplate Hooks Left Side Faceplate Bracket Trim Flange Slots SurroundOperating Instructions First Fire Shutdown ProcedureCopy of Lighting Instruction Plate Maintenance Maintenance InstructionsLOG Replacement GOLD-PLATED TrimDoor Glass FAN Maintenance Replacement Flush Glass ReplacementAeration Adjustment Rod Bay Glass RemovalParts List DescriptionBurner Assembly & Log Set Bay Door Flush Door400-939 Valve Access Faceplate 402-919 Complete Faceplate Set with Black Trim Oversize400-917 Complete Custom Faceplate Set 402-918 Complete Faceplate Set with Black Trim StandardParts List Hampton Cast Faceplate Assembly Warranty ConditionsInstaller Please complete the following information