INSTALLATION
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The FPI Gas Insert must be installed in ac- cordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to de- termine the need for a permit prior to starting the installation.
NOTE: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or warranty. This appliance can be used with a thermostat.
FOR YOUR SAFETY
This appliance requires air for proper combus- tion. Always provide adequate combustion and ventilation air. Follow instructions and information in CAN/CGA B149 (in Canada) or the National Fuel Gas CodeANSI Z223.1 (in the USA), regarding requirements for combustion and ventilation air.
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit must be disconnected.
Gas Input Capacity: |
|
Natural Gas | 30,000 Btu/h |
Propane | 27,500 Btu/h |
Min. Output (Fan Off) |
|
Natural Gas | 21,000 Btu/h |
Propane | 19,400 Btu/h |
Max. Output (Fan On) |
|
Natural Gas | 22,000 Btu/h |
Propane | 20,500 Btu/h |
Fuels: Approved for use with both natural gas, and propane. Approved as is for use at 0' to 2,000'. With a fi eld installed conversion kit 0' - 4,500'.
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 127 CFM.
Log Set: Ceramic fi bre, 7 per set.
Vent System: Minimum 4"
GAS PRESSURE TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at test pres- sures over 1/2 psig (3.45 kPa).
POLICY FOR SOLID FUEL BURNING AND FACTORY BUILT FIREPLACES
The FPI
1)Installer must mechanically attach the sup- plied label to the inside of the fi rebox of the fi replace into which the gas fi replace insert is installed.
WARNING: This fi replace has been con- verted for use with a gas fi replace insert only and cannot be used for burning wood or solid fuels unless all original parts have
2)Do not cut any
3)
4)The fi replace fl ue damper can be fully blocked open or removed for installation of the gas fi replace insert.
5)The fi replace and fi replace chimney must be clean and in good working order and constructed of
6)The chimney cleanouts must fi t properly.
7)Refractory (fi rebricks), glass doors, screen rails, screen mesh and log grates can be removed from the fi replace before installing the gas fi replace insert.
8)Smoke shelves, shields and baffl es may be removed if attached by mechanical fasten-
ers. If any part is removed it must not weaken the structural integrity of the factory built.
9)Trim panels or surrounds shall not seal ventilation openings in the fi replace.
BEFORE YOU START
Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
General Safety Information
1)The appliance installation must conform with local codes or in the absence of local codes, with CAN/CGA B149 (in Canada) or the National Fuel Gas Code ANSI Z223.1. This appliance should be installed by a qualifi ed gas fi tter technician only.
2)Installation and repair should be done by a qualified service person.
3)The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, animal hair, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
4)See general construction and assembly instructions. This appliance may only be installed in a vented, noncombustible fi re- place.
5)This appliance is Listed for bedroom instal- lations. In Canada room heaters must be installed with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.
6)This unit is not approved for installation into a mobile home.
7)Always connect this insert to a vent sys- tem venting to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is properly sized and is of adequate height to provide the proper draft.
8)Inspect the venting system annually for blockage and any signs of deterioration.
9)Any glass removed for servicing must be replaced prior to operating the appliance.
10)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.
6 | FPI |