Installation (for qualified installers only)

1 1

Facing Requirements

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.

WARNING: Do not use adhesive to secure the cement board or facing. The high temperatures of the fireplace may cause adhesives to emit odors. Use mastic or thin set (or other non-combustible, non-odorous adherent) to attach the facing to the cement board.

NOTE: Screws may be used to secure the cement board to the fireplace. Do not penetrate the fireplace more than 3/4”

10" Min.

30" Arch face 28-1/2" Rectangular face 30-3/8" Architectural face

Base of

Fireplace

Rectangular Face

Arch Face

36" Arch face

38" Rectangular face

36-1/4" Architectural face

The fireplace requires a concrete board (or other non-combustible) extending from the header to the floor and to the framing members on both sides. Do not use sheetrock, plywood or other combustible.

Header

Non-combustible Facing

4-1/2" Min. (both sides)

Facing Over 1" Thick

Architectural faces require a 5/8" gap above the face for face installation.

If the facing material is over 1" thick (e.g. brick, river rock), install the facing around the perimeter of the face. You may wish to make a face template (see the illustration to the right). If using an arch face, you may wish to order the optional set-up face:

Arch Set-Up Face

Part # 98500692

For rectangular faces, use a piece of plywood cut to the dimensions shown on page 13 (add 1/8" to each dimension).

Artisan faces vary in size. Use the face being installed to create a template.

The brick facing must meet the same requirements listed “Facing Requirements” above.

Center

Line

Face Template

Mounting

Holes

-3/4

19

-3/8

 

16

Note: The brick tucks below the face template.

-1/2 4 The face template should be 1/8” larger than the

finished face. Attach the template to the fireplace using the face attachment screws. Then while building the face, use the template to support the face material and ensure the facing does not overlap the face.

7/8”

Note: if using a brick hearth, the fireplace will need to be raised to accommodate the 1” gap betwen the face and the base of the fireplace. For 2-1/2” thick brick this works out to approximately 1-5/8”.

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Image 11
Contents If YOU Smell GAS Travis Industries 4040708 0 0 1 1 6 2IntroductionIntroduction Important Information Table of Contents If YOU Smell GAS Safety PrecautionsThis Manual Natural Gas Propane 6Features and SpecificationsFeatures Installation Options Packing List Additional Items Required Installation WarningsInstallation Overview Clearances Fireplace Placement RequirementsMinimum Framing Dimensions Raised Fireplaces Corner InstallationsFloor Mounted Fireplaces Hearth RequirementsFacing Over 1 Thick Facing RequirementsTOP View Facing DetailModifying the Face Angle for Rectangular Faces Installation forFace Dimensions Side View Facing and Hearth ExamplesDV Fireplace Non-Combustible Mantels Mantel RequirementsCombustible Mantels Part Numbers for 6-5/8 Diameter Vent Vent RequirementsAltitude Considerations Use of 8 Diameter PipeHorizontal Vent Requirements Vent InstallationMeasuring Vent Lengths Approved Vent ConfigurationsRestrictor Position ElbowsZero or Two 45 Offsets 0feet 5feet 10feet 12max 10 max Feet Horizontal Terminations using 6-5/8 Diameter VentFeet 5feet 10feet 15feet 20feet 25max 40 max Horizontal Terminations using 8 Diameter Vent Termination Requirements see the illustration below Gas Inlet Pressure Gas Line RequirementsFuel Gas Line ConnectionElectrical Connection Re-Attaching the Glass Frame Finalizing the InstallationGlass Frame Removal Spring Pin Installation 8Finalizing the InstallationTop Front View Side View 0Finalizing the InstallationStep Correct Fine Tuning the EMBER-FYRE Burner 2Finalizing the InstallationLocation of Controls See explanation below Operation3Before You Begin Starting The Pilot Flame 4OperationTurning the Fireplace On and Off Adjusting the Flame HeightStarting the Fireplace for the First Time Normal Operating Sounds Adjusting the Blower SpeedOptional Power Heat Duct 6OperationMaintaining Your Fireplaces Appearance Maintenance3Yearly Service Procedure Troubleshooting MaintenanceWhat Prevents Gas Buildup How this Fireplace WorksWhat Turns the Main Burners On and Off Replacement Parts List 0MaintenanceWiring Diagram Minimum Clearances to Combustibles Safety LabelYears 1 & 2 Coverage Parts & Labor 2Limited 7 Year WarrantyLP Conversion Instructions Burner ReplacementOptional Equipment for qualified installers only Slotted Screwdriver Or T-20 Torx Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions 2Index

36 DV EFIII specifications

The FireplaceXtrordinair 36 DV EFIII is a remarkable direct vent gas fireplace that blends innovative technology with aesthetic appeal, making it an ideal addition to any modern living space. Renowned for its exceptional design and performance, this fireplace provides both warmth and ambience while ensuring efficiency and safety.

One of the standout features of the 36 DV EFIII is its impressive heating capacity. It boasts a maximum output of up to 28,000 BTUs, providing sufficient heat to effectively warm large areas while maintaining energy efficiency. This model is equipped with a powerful fan system that circulates warm air throughout the room, enhancing comfort levels even in colder months.

The FireplaceXtrordinair 36 DV EFIII incorporates advanced technology, including a state-of-the-art electronic ignition system. This feature allows for quick and easy startups without the hassle of traditional matches or lighters. Additionally, the unit is designed with a modulating gas valve, which adjusts the flame height to optimize both heat output and fuel consumption, resulting in impressive energy savings.

The fireplace is also designed with versatility in mind. It offers customizable options, including various decorative media, such as traditional logs, rocks, or contemporary glass, allowing homeowners to create the desired aesthetic that complements their interior design. The 36 DV EFIII is available with multiple front styles and finishes, ensuring it integrates seamlessly with any décor.

Safety is paramount with the FireplaceXtrordinair 36 DV EFIII, featuring a sealed combustion system that draws air from outside the home, reducing the risk of indoor pollution. The direct vent design ensures that all exhaust is expelled outside, providing a clean and safe burning experience.

Another notable characteristic of the 36 DV EFIII is its easy maintenance. The unit is designed for straightforward cleaning, with an accessible glass front that can be easily removed for periodic maintenance. This convenience makes it an attractive option for homeowners looking for a user-friendly fireplace solution.

In conclusion, the FireplaceXtrordinair 36 DV EFIII is a premium direct vent gas fireplace that combines elegance, efficiency, and safety. With its impressive heating capabilities, customizable features, and advanced technology, it stands out as an excellent choice for anyone looking to enhance their home with a high-quality fireplace.