FireplaceXtrordinair 36 DV EFIII owner manual Termination Requirements see the illustration below

Page 24

2 4

Installation (for qualified installers only)

Termination Requirements (see the illustration below)

AMinimum 9" clearance from any door or window

BMinimum 12" above any grade, veranda, porch, deck or balcony

CMinimum 12" from outside corner walls

DMinimum 12" from inside corner walls

EMinimum 11" clearance below unventilated soffits or roof surfaces Minimum 18" clearance below ventilated soffits

Minimum 6" clearance from roof eaves NOTE: Vinyl surfaces require 24"

Roof

Surface

11” Min.

Roof

6” Min. Eaves

FMinimum 18" clearance below a veranda, porch, deck or balcony (must have two open sides)

GMinimum 48" clearance from any adjacent building

HMinimum 84" clearance above any grade when adjacent to public walkways or driveways NOTE: may not be used over a walkway or driveway shared by an adjacent building

IMinimum 48" clearance from any mechanical air supply inlet, 72" for Canada

JMinimum 36" clearance above and 48” below and to the sides of non-mechanical air supply inlet

KMinimum 36" from the area above the meter/regulator (vent outlet)

LMinimum 36" from the meter/regulator (vent outlet)

MMinimum 12” above the roof line (for vertical terminations)

*N o t e : In Canada the vent termination must be a minimum 2' (.6 M) tall and 2' (.6 M) above any portion of the roof within 10' (3 M) of the vent.

NMinimum 24” horizontal clearance to any surface (such as an exterior wall) – for vertical terminations

E

N

M

E

A

K

G A

F

D C I

L

B

NOTE: Measure clearances to the nearest edge of the exhaust hood.

E

J

H

Use the vinyl siding standoff (#950) when installing on an exterior with vinyl siding.

Vent termination must not be located where it will become plugged by snow or other material

These clearances meet UMC-1994 and the CNA/CGA-B149 code standards.

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Image 24
Contents If YOU Smell GAS 2Introduction Introduction Important InformationTravis Industries 4040708 0 0 1 1 6 Table of Contents Safety Precautions If YOU Smell GASThis Manual 6Features and Specifications Features Installation OptionsNatural Gas Propane Installation Warnings Installation OverviewPacking List Additional Items Required Fireplace Placement Requirements Minimum Framing DimensionsClearances Corner Installations Raised FireplacesHearth Requirements Floor Mounted FireplacesFacing Requirements Facing Over 1 ThickFacing Detail TOP ViewInstallation for Face DimensionsModifying the Face Angle for Rectangular Faces Facing and Hearth Examples Side ViewDV Fireplace Mantel Requirements Combustible MantelsNon-Combustible Mantels Vent Requirements Altitude ConsiderationsUse of 8 Diameter Pipe Part Numbers for 6-5/8 Diameter VentVent Installation Horizontal Vent RequirementsApproved Vent Configurations Restrictor PositionElbows Measuring Vent LengthsZero or Two 45 Offsets Horizontal Terminations using 6-5/8 Diameter Vent 0feet 5feet 10feet 12max 10 max FeetFeet 5feet 10feet 15feet 20feet 25max 40 max Horizontal Terminations using 8 Diameter Vent Termination Requirements see the illustration below Gas Line Requirements FuelGas Line Connection Gas Inlet PressureElectrical Connection Finalizing the Installation Re-Attaching the Glass Frame8Finalizing the Installation Glass Frame Removal Spring Pin InstallationTop 0Finalizing the Installation StepFront View Side View Correct 2Finalizing the Installation Fine Tuning the EMBER-FYRE BurnerOperation3 Before You BeginLocation of Controls See explanation below 4Operation Starting The Pilot FlameAdjusting the Flame Height Starting the Fireplace for the First TimeTurning the Fireplace On and Off Adjusting the Blower Speed Optional Power Heat Duct6Operation Normal Operating SoundsMaintenance3 Yearly Service ProcedureMaintaining Your Fireplaces Appearance Maintenance TroubleshootingHow this Fireplace Works What Turns the Main Burners On and OffWhat Prevents Gas Buildup 0Maintenance Wiring DiagramReplacement Parts List Safety Label Minimum Clearances to Combustibles2Limited 7 Year Warranty Years 1 & 2 Coverage Parts & LaborBurner Replacement LP Conversion InstructionsOptional Equipment for qualified installers only Slotted Screwdriver Or T-20 Torx Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions 2Index

36 DV EFIII specifications

The FireplaceXtrordinair 36 DV EFIII is a remarkable direct vent gas fireplace that blends innovative technology with aesthetic appeal, making it an ideal addition to any modern living space. Renowned for its exceptional design and performance, this fireplace provides both warmth and ambience while ensuring efficiency and safety.

One of the standout features of the 36 DV EFIII is its impressive heating capacity. It boasts a maximum output of up to 28,000 BTUs, providing sufficient heat to effectively warm large areas while maintaining energy efficiency. This model is equipped with a powerful fan system that circulates warm air throughout the room, enhancing comfort levels even in colder months.

The FireplaceXtrordinair 36 DV EFIII incorporates advanced technology, including a state-of-the-art electronic ignition system. This feature allows for quick and easy startups without the hassle of traditional matches or lighters. Additionally, the unit is designed with a modulating gas valve, which adjusts the flame height to optimize both heat output and fuel consumption, resulting in impressive energy savings.

The fireplace is also designed with versatility in mind. It offers customizable options, including various decorative media, such as traditional logs, rocks, or contemporary glass, allowing homeowners to create the desired aesthetic that complements their interior design. The 36 DV EFIII is available with multiple front styles and finishes, ensuring it integrates seamlessly with any décor.

Safety is paramount with the FireplaceXtrordinair 36 DV EFIII, featuring a sealed combustion system that draws air from outside the home, reducing the risk of indoor pollution. The direct vent design ensures that all exhaust is expelled outside, providing a clean and safe burning experience.

Another notable characteristic of the 36 DV EFIII is its easy maintenance. The unit is designed for straightforward cleaning, with an accessible glass front that can be easily removed for periodic maintenance. This convenience makes it an attractive option for homeowners looking for a user-friendly fireplace solution.

In conclusion, the FireplaceXtrordinair 36 DV EFIII is a premium direct vent gas fireplace that combines elegance, efficiency, and safety. With its impressive heating capabilities, customizable features, and advanced technology, it stands out as an excellent choice for anyone looking to enhance their home with a high-quality fireplace.