FireplaceXtrordinair 36 DV EFIII Finalizing the Installation, Re-Attaching the Glass Frame

Page 27

Finalizing the Installation

2 7

1Remove the glass frame (and arch covers) following the directions below. Warning: The appliance must be completely cool before removing the glass.

N o t e : If using an arch face, attach the arch covers after re-installing the glass.

Spring Pin

Open the four latches holding the glass

a frame in place (start with the bottomTop of

Firebox

two) - follow the directions shown to the right.

Glass

 

Glass Frame

 

b

Lift the glass frame up and

 

pull it forward to remove.

NOTE:

 

 

 

 

You may need to lift

 

 

the glass frame

 

 

while re-attaching.

Re-Attaching the Glass Frame:

a)Hang the glass frame on the firebox.

b)While holding in place, attach the upper latches

Insert the 1/4” key into the spring pin.

Twist 1/4 turn.

(follow the instructions to the right in reverse).

Latch Bracket

The spring pin will disengage from the

c) Lift the glass frame slightly and attach the lower latches.

Arch Covers (both sides)

latch bracket, opening the latch.

Glass

Frame

Arch Cover

Glass

The arch covers (included in the owner's pack) block light from exiting the scroll work on arched faces.

The covers hang on the glass frame.

Arch Faces:

Attach arch covers before installing the face.

Rectangular Faces:

Discard the arch covers.

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Image 27 Contents
If YOU Smell GAS 2Introduction Introduction Important InformationTravis Industries 4040708 0 0 1 1 6 Table of Contents If YOU Smell GAS Safety PrecautionsThis Manual 6Features and Specifications Features Installation OptionsNatural Gas Propane Installation Warnings Installation OverviewPacking List Additional Items Required Fireplace Placement Requirements Minimum Framing DimensionsClearances Raised Fireplaces Corner InstallationsFloor Mounted Fireplaces Hearth RequirementsFacing Over 1 Thick Facing RequirementsTOP View Facing DetailInstallation for Face DimensionsModifying the Face Angle for Rectangular Faces Side View Facing and Hearth ExamplesDV Fireplace Mantel Requirements Combustible MantelsNon-Combustible Mantels Part Numbers for 6-5/8 Diameter Vent Vent RequirementsAltitude Considerations Use of 8 Diameter PipeHorizontal Vent Requirements Vent InstallationMeasuring Vent Lengths Approved Vent ConfigurationsRestrictor Position ElbowsZero or Two 45 Offsets 0feet 5feet 10feet 12max 10 max Feet Horizontal Terminations using 6-5/8 Diameter VentFeet 5feet 10feet 15feet 20feet 25max 40 max Horizontal Terminations using 8 Diameter Vent Termination Requirements see the illustration below Gas Inlet Pressure Gas Line RequirementsFuel Gas Line ConnectionElectrical Connection Re-Attaching the Glass Frame Finalizing the InstallationGlass Frame Removal Spring Pin Installation 8Finalizing the InstallationTop 0Finalizing the Installation StepFront View Side View Correct Fine Tuning the EMBER-FYRE Burner 2Finalizing the InstallationOperation3 Before You BeginLocation of Controls See explanation below Starting The Pilot Flame 4OperationAdjusting the Flame Height Starting the Fireplace for the First TimeTurning the Fireplace On and Off Normal Operating Sounds Adjusting the Blower SpeedOptional Power Heat Duct 6OperationMaintenance3 Yearly Service ProcedureMaintaining Your Fireplaces Appearance Troubleshooting MaintenanceHow this Fireplace Works What Turns the Main Burners On and OffWhat Prevents Gas Buildup 0Maintenance Wiring DiagramReplacement Parts List Minimum Clearances to Combustibles Safety LabelYears 1 & 2 Coverage Parts & Labor 2Limited 7 Year WarrantyLP Conversion Instructions Burner ReplacementOptional Equipment for qualified installers only Slotted Screwdriver Or T-20 Torx Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions 2Index