Optional Equipment (for qualified installers only) 5 1

Run the free wire from the rheostat junction box to the fireplace. Follow the directions below to connect the heat duct circuit to the fireplace.

a

Remove the cover from the

fireplace junction box.

Note: you may need to loosen this cable clamp to ease removal of the cover plate.

Insert the sheathed cable from the rheostat through a c cable clamp and push the cable clamp into the knock-out

hole to secure it in place. Once the wires are attached, tighten the clamp to secure the cable.

b

Nutdriver

Power

1/4"

Source

 

for

 

Fireplace

Electrical Connector (included with the heat duct kit)

Standard

Screwdriver e

Replace the cover removed in step "a".

To optional second power heat vent (use the center knock-out).

Standard

Screwdriver Pry out and discard this knock-out.

Attach the common (white), ground (exposed or green) wires, and hot d (black) wires from the cable leading to the rheostat to the molex

connector. Then attach the molex connector to the fireplace.

MAINTENANCE INSTRUCTIONS

Once a year the grate should be removed and the blower area cleaned. Use a vacuum to clean around the squirrel-cage blower, being careful not to damage any of the blades

Phillips Screwdriver

Use a vacuum cleaner to remove any debris from the power vent blower.

Grill

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Image 51 Contents
If YOU Smell GAS 2Introduction Introduction Important InformationTravis Industries 4040708 0 0 1 1 6 Table of Contents If YOU Smell GAS Safety PrecautionsThis Manual 6Features and Specifications Features Installation OptionsNatural Gas Propane Installation Warnings Installation OverviewPacking List Additional Items Required Fireplace Placement Requirements Minimum Framing DimensionsClearances Raised Fireplaces Corner InstallationsFloor Mounted Fireplaces Hearth RequirementsFacing Over 1 Thick Facing RequirementsTOP View Facing DetailInstallation for Face DimensionsModifying the Face Angle for Rectangular Faces Side View Facing and Hearth ExamplesDV Fireplace Mantel Requirements Combustible MantelsNon-Combustible Mantels Part Numbers for 6-5/8 Diameter Vent Vent RequirementsAltitude Considerations Use of 8 Diameter PipeHorizontal Vent Requirements Vent InstallationMeasuring Vent Lengths Approved Vent ConfigurationsRestrictor Position ElbowsZero or Two 45 Offsets 0feet 5feet 10feet 12max 10 max Feet Horizontal Terminations using 6-5/8 Diameter VentFeet 5feet 10feet 15feet 20feet 25max 40 max Horizontal Terminations using 8 Diameter Vent Termination Requirements see the illustration below Gas Inlet Pressure Gas Line RequirementsFuel Gas Line ConnectionElectrical Connection Re-Attaching the Glass Frame Finalizing the InstallationGlass Frame Removal Spring Pin Installation 8Finalizing the InstallationTop 0Finalizing the Installation StepFront View Side View Correct Fine Tuning the EMBER-FYRE Burner 2Finalizing the InstallationOperation3 Before You BeginLocation of Controls See explanation below Starting The Pilot Flame 4OperationAdjusting the Flame Height Starting the Fireplace for the First TimeTurning the Fireplace On and Off Normal Operating Sounds Adjusting the Blower SpeedOptional Power Heat Duct 6OperationMaintenance3 Yearly Service ProcedureMaintaining Your Fireplaces Appearance Troubleshooting MaintenanceHow this Fireplace Works What Turns the Main Burners On and OffWhat Prevents Gas Buildup 0Maintenance Wiring DiagramReplacement Parts List Minimum Clearances to Combustibles Safety LabelYears 1 & 2 Coverage Parts & Labor 2Limited 7 Year WarrantyLP Conversion Instructions Burner ReplacementOptional Equipment for qualified installers only Slotted Screwdriver Or T-20 Torx Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions 2Index