FireplaceXtrordinair 36 DV EFIII 0Finalizing the Installation, Step, Front View Side View

Page 30

3 0Finalizing the Installation

Step 2 Install the twigs and ember chunk (see the illustration below).

Place the left and right

twigs as shown.

Place the ember

chunk as shown.

Step 3

Install the embers along the front of the burner (see the illustrations below).

 

Do not place the embers over the burner holes.

Front View

Side View

!We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the firebox, ensuring gas does not build up.

3Turn on the gas to the fireplace. Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start the main burner. Leak test all gas joints again.

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Image 30
Contents If YOU Smell GAS 2Introduction Introduction Important InformationTravis Industries 4040708 0 0 1 1 6 Table of Contents Safety Precautions If YOU Smell GASThis Manual 6Features and Specifications Features Installation OptionsNatural Gas Propane Installation Warnings Installation OverviewPacking List Additional Items Required Fireplace Placement Requirements Minimum Framing DimensionsClearances Corner Installations Raised FireplacesHearth Requirements Floor Mounted FireplacesFacing Requirements Facing Over 1 ThickFacing Detail TOP ViewInstallation for Face DimensionsModifying the Face Angle for Rectangular Faces Facing and Hearth Examples Side ViewDV Fireplace Mantel Requirements Combustible MantelsNon-Combustible Mantels Use of 8 Diameter Pipe Vent RequirementsAltitude Considerations Part Numbers for 6-5/8 Diameter VentVent Installation Horizontal Vent RequirementsElbows Approved Vent ConfigurationsRestrictor Position Measuring Vent LengthsZero or Two 45 Offsets Horizontal Terminations using 6-5/8 Diameter Vent 0feet 5feet 10feet 12max 10 max FeetFeet 5feet 10feet 15feet 20feet 25max 40 max Horizontal Terminations using 8 Diameter Vent Termination Requirements see the illustration below Gas Line Connection Gas Line RequirementsFuel Gas Inlet PressureElectrical Connection Finalizing the Installation Re-Attaching the Glass Frame8Finalizing the Installation Glass Frame Removal Spring Pin InstallationTop 0Finalizing the Installation StepFront View Side View Correct 2Finalizing the Installation Fine Tuning the EMBER-FYRE BurnerOperation3 Before You BeginLocation of Controls See explanation below 4Operation Starting The Pilot FlameAdjusting the Flame Height Starting the Fireplace for the First TimeTurning the Fireplace On and Off 6Operation Adjusting the Blower SpeedOptional Power Heat Duct Normal Operating SoundsMaintenance3 Yearly Service ProcedureMaintaining Your Fireplaces Appearance Maintenance TroubleshootingHow this Fireplace Works What Turns the Main Burners On and OffWhat Prevents Gas Buildup 0Maintenance Wiring DiagramReplacement Parts List Safety Label Minimum Clearances to Combustibles2Limited 7 Year Warranty Years 1 & 2 Coverage Parts & LaborBurner Replacement LP Conversion InstructionsOptional Equipment for qualified installers only Slotted Screwdriver Or T-20 Torx Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions 2Index

36 DV EFIII specifications

The FireplaceXtrordinair 36 DV EFIII is a remarkable direct vent gas fireplace that blends innovative technology with aesthetic appeal, making it an ideal addition to any modern living space. Renowned for its exceptional design and performance, this fireplace provides both warmth and ambience while ensuring efficiency and safety.

One of the standout features of the 36 DV EFIII is its impressive heating capacity. It boasts a maximum output of up to 28,000 BTUs, providing sufficient heat to effectively warm large areas while maintaining energy efficiency. This model is equipped with a powerful fan system that circulates warm air throughout the room, enhancing comfort levels even in colder months.

The FireplaceXtrordinair 36 DV EFIII incorporates advanced technology, including a state-of-the-art electronic ignition system. This feature allows for quick and easy startups without the hassle of traditional matches or lighters. Additionally, the unit is designed with a modulating gas valve, which adjusts the flame height to optimize both heat output and fuel consumption, resulting in impressive energy savings.

The fireplace is also designed with versatility in mind. It offers customizable options, including various decorative media, such as traditional logs, rocks, or contemporary glass, allowing homeowners to create the desired aesthetic that complements their interior design. The 36 DV EFIII is available with multiple front styles and finishes, ensuring it integrates seamlessly with any décor.

Safety is paramount with the FireplaceXtrordinair 36 DV EFIII, featuring a sealed combustion system that draws air from outside the home, reducing the risk of indoor pollution. The direct vent design ensures that all exhaust is expelled outside, providing a clean and safe burning experience.

Another notable characteristic of the 36 DV EFIII is its easy maintenance. The unit is designed for straightforward cleaning, with an accessible glass front that can be easily removed for periodic maintenance. This convenience makes it an attractive option for homeowners looking for a user-friendly fireplace solution.

In conclusion, the FireplaceXtrordinair 36 DV EFIII is a premium direct vent gas fireplace that combines elegance, efficiency, and safety. With its impressive heating capabilities, customizable features, and advanced technology, it stands out as an excellent choice for anyone looking to enhance their home with a high-quality fireplace.