6Features and Specifications
Features: | Installation Options: | ||
- Works During Power Outages (millivolt system) | - Residential or Mobile Home | ||
- | High Efficiency | - Straight or Corner Placement | |
- Optional Thermostat or Remote Control | - Flush or Recessed Face | ||
- Realistic "Wood Fire" Look | - Raised or Floor Hearth | ||
- Internal or External Chase | |||
- Quiet Blower for Effective Heat Distribution | |||
- Horizontal or Vertical Vent | |||
- | Convenient Operating Controls | ||
- | - Power Heat Duct | ||
- | Low Maintenance |
|
Heating Specifications:
Natural Gas | Propane |
Approximate Heating Capacity (in square feet)* | 1,200 - 2,250 | 1200 - 2,250 |
Maximum BTU Input Per Hour | 43,000 | 43,000 |
Minimum BTU Output on Low (with blowers on) | 23,384 | 20,800 |
Efficiency** (with blowers on) | Up to 79% | Up to 80% |
AFUE (Annual Fuel Utilization Efficiency) | 72% | 73% |
*Heating capacity will vary with floor plan, insulation, use of Power Heat Duct, and outside temperature.
**Efficiency rating is a product thermal efficiency rating determined under continuous operation independent of installed system.
| Vent has an external diameter of | |
|
| The electrical connection is |
| made in the lower right rear | |
corner. |
|
|
| |
|
|
| |
Power Heat Vent |
|
| |
|
|
| |
|
|
| |
1/2" |
| ||
|
| ||
|
|
| 23" |
| 40" |
| |
|
|
| |
Nail Down Plate |
|
|
|
(used to secure the |
|
| 1" |
fireplace to the |
|
| |
| 1" |
| |
floor) |
| ||
|
|
Weight: 250 Lbs.
* Includes the 1/2" clearance | ||
|
| |
|
Gas Inlet (on both sides)
Travis Industries | 4040708 | 1 0 0 - 0 1 1 6 0 |