FireplaceXtrordinair 36 DV EFIII owner manual Vent Requirements, Altitude Considerations

Page 17

Installation (for qualified installers only)

1 7

Vent Requirements

!The vent must maintain the required clearance to combustible materials to prevent a fire (see “Clearances” below). Do not fill air spaces with insulation.

!The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use it's own separate vent system.

Altitude Considerations

This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing we have found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.

!Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter.

Clearances

Minimum 1” clearance to all combustibles (measured from the outside of the pipe) e x c e p t for the following:

When using 6-5/8" vent, a

 

2" Clearance

With any vertical

1" Clearance

 

vent directly off the

 

 

 

 

 

 

 

horizontal termination, and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fireplace, the

 

 

 

 

 

 

 

an elbow directly off the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clearance is 1".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

top of the fireplace, a 2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clearance is required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

above the horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sections (1" to the side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and below).

 

 

 

 

Max. 3'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use of 8” Diameter Pipe

Most venting configurations use 6-5/8” diameter vent. To achieve longer horizontal runs (over 12’) with a horizontal termination, 8” dia. Simpson Duravent type GS Direct Vent may be used. See the section “Horizontal Terminations using 8” Diameter Vent” for details. Part Numbers are listed below.

Straight Lengths

Terminations

1208B

6" Pipe Length, Black

1284

Horizontal Square Termination

1207B

9" Pipe Length, Black

1285

Hor. High Wind Termination

1250

Vinyl Siding Stand-off

1206B

12" Pipe Length, Black

 

 

1204B

24" Pipe Length, Black

Elbows

1203B

36" Pipe Length, Black

1202B

48" Pipe Length, Black

1245B

45° Elbow, Black

1211B

11” to 14-5/8" Adjustable Pipe,

1290B

90° Elbow, Black

Black

 

 

 

Penetration, Support

1242

Wall Firestop

1241

Cathedral Ceiling Support Box

1263

Ceiling Fire-stop

1288

Wall Strap

Adapter (6-5/8” to 8” dia.)

925T DV GS 6-5/8” to 8” Increaser

Part Numbers for 6-5/8” Diameter Vent

Use Model GS Direct Vent manufactured by Simpson Dura-Vent only. Follow the installation instructions included with the vent. For the nearest Simpson Dura-Vent supplier, call (800) 835-4429. Vent part numbers and descriptions are listed below.

Straight Lengths

908B 6" Pipe Length, Black (interior)

907B 9" Pipe Length, Black (interior)

90612" Pipe Length, Galvanized

906B 12" Pipe Length, Black (interior)

90424" Pipe Length, Galvanized

904B 24" Pipe Length, Black (interior)

90336" Pipe Length, Galvanized

903B 36" Pipe Length, Black (interior)

90248" Pipe Length, Galvanized

902B 48" Pipe Length, Black (interior)

911B 11" to 14 5/8" Adjustable, Black (interior)

Vent Terminations

981Snorkel Termination (36" rise) (for basement or raised termination installations)

982Snorkel Termination (14" rise) (for basement or raised termination installations)

984Horizontal Square Termination

950Vinyl Siding Stand-off

991High Wind Vertical Termination

Elbows

990 90• Elbow

990B 90• Elbow, Black (interior)

Penetration, Support

942 Wall Thimble

941Cathedral Ceiling Support Box

943Flashing, 0/12 to 6/12 Roof Pitch

943S Flashing, 7/12 to 12/12 Roof Pitch

953Storm Collar

963Ceiling Fire-stop

988Wall Strap

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Image 17
Contents If YOU Smell GAS Travis Industries 4040708 0 0 1 1 6 2IntroductionIntroduction Important Information Table of Contents If YOU Smell GAS Safety PrecautionsThis Manual Natural Gas Propane 6Features and SpecificationsFeatures Installation Options Packing List Additional Items Required Installation WarningsInstallation Overview Clearances Fireplace Placement RequirementsMinimum Framing Dimensions Raised Fireplaces Corner InstallationsFloor Mounted Fireplaces Hearth RequirementsFacing Over 1 Thick Facing RequirementsTOP View Facing DetailModifying the Face Angle for Rectangular Faces Installation forFace Dimensions Side View Facing and Hearth ExamplesDV Fireplace Non-Combustible Mantels Mantel RequirementsCombustible Mantels Altitude Considerations Vent RequirementsUse of 8 Diameter Pipe Part Numbers for 6-5/8 Diameter VentHorizontal Vent Requirements Vent InstallationRestrictor Position Approved Vent ConfigurationsElbows Measuring Vent LengthsZero or Two 45 Offsets 0feet 5feet 10feet 12max 10 max Feet Horizontal Terminations using 6-5/8 Diameter VentFeet 5feet 10feet 15feet 20feet 25max 40 max Horizontal Terminations using 8 Diameter Vent Termination Requirements see the illustration below Fuel Gas Line RequirementsGas Line Connection Gas Inlet PressureElectrical Connection Re-Attaching the Glass Frame Finalizing the InstallationGlass Frame Removal Spring Pin Installation 8Finalizing the InstallationTop Front View Side View 0Finalizing the InstallationStep Correct Fine Tuning the EMBER-FYRE Burner 2Finalizing the InstallationLocation of Controls See explanation below Operation3Before You Begin Starting The Pilot Flame 4OperationTurning the Fireplace On and Off Adjusting the Flame HeightStarting the Fireplace for the First Time Optional Power Heat Duct Adjusting the Blower Speed6Operation Normal Operating SoundsMaintaining Your Fireplaces Appearance Maintenance3Yearly Service Procedure Troubleshooting MaintenanceWhat Prevents Gas Buildup How this Fireplace WorksWhat Turns the Main Burners On and Off Replacement Parts List 0MaintenanceWiring Diagram Minimum Clearances to Combustibles Safety LabelYears 1 & 2 Coverage Parts & Labor 2Limited 7 Year WarrantyLP Conversion Instructions Burner ReplacementOptional Equipment for qualified installers only Slotted Screwdriver Or T-20 Torx Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions 2Index

36 DV EFIII specifications

The FireplaceXtrordinair 36 DV EFIII is a remarkable direct vent gas fireplace that blends innovative technology with aesthetic appeal, making it an ideal addition to any modern living space. Renowned for its exceptional design and performance, this fireplace provides both warmth and ambience while ensuring efficiency and safety.

One of the standout features of the 36 DV EFIII is its impressive heating capacity. It boasts a maximum output of up to 28,000 BTUs, providing sufficient heat to effectively warm large areas while maintaining energy efficiency. This model is equipped with a powerful fan system that circulates warm air throughout the room, enhancing comfort levels even in colder months.

The FireplaceXtrordinair 36 DV EFIII incorporates advanced technology, including a state-of-the-art electronic ignition system. This feature allows for quick and easy startups without the hassle of traditional matches or lighters. Additionally, the unit is designed with a modulating gas valve, which adjusts the flame height to optimize both heat output and fuel consumption, resulting in impressive energy savings.

The fireplace is also designed with versatility in mind. It offers customizable options, including various decorative media, such as traditional logs, rocks, or contemporary glass, allowing homeowners to create the desired aesthetic that complements their interior design. The 36 DV EFIII is available with multiple front styles and finishes, ensuring it integrates seamlessly with any décor.

Safety is paramount with the FireplaceXtrordinair 36 DV EFIII, featuring a sealed combustion system that draws air from outside the home, reducing the risk of indoor pollution. The direct vent design ensures that all exhaust is expelled outside, providing a clean and safe burning experience.

Another notable characteristic of the 36 DV EFIII is its easy maintenance. The unit is designed for straightforward cleaning, with an accessible glass front that can be easily removed for periodic maintenance. This convenience makes it an attractive option for homeowners looking for a user-friendly fireplace solution.

In conclusion, the FireplaceXtrordinair 36 DV EFIII is a premium direct vent gas fireplace that combines elegance, efficiency, and safety. With its impressive heating capabilities, customizable features, and advanced technology, it stands out as an excellent choice for anyone looking to enhance their home with a high-quality fireplace.