FireplaceXtrordinair 36 DV EFIII owner manual Gas Line Requirements, Fuel, Gas Line Connection

Page 25

Installation (for qualified installers only)

2 5

Gas Line Requirements

!The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1 and the requirements listed below.

!The fireplace and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig. For pressures under 1/2 psig, isolate the gas supply piping by closing the manual shutoff valve.

!Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.

Fuel

This fireplace is designed either for natural gas or for propane (but not for both). Check the sticker on the top of the gas control valve to make sure the correct fuel is used.

Gas Line Connection

A manual shutoff valve is required for installation (within 3’ of the heater or inside the fireplace). T- Handle gas cocks are required in Massachusetts in compliance with code 248CMR.

Installation must be performed by a qualified installer, service agency or the gas supplier (In Massachusetts a licensed plumber/gasfitter).

The 1" diameter access hole is located 1-7/8" above the base of the fireplace. Cut an "X" in the gasket covering the inlet and insert the gas line through the gasket.

13-3/4"

6-1/2"5-1/2"

-- OR --

-- OR --

The included

fitting accepts a

3/8" M.P.T. or

1/2" F.P.T.

A shutoff valve may be placed within the fireplace

If the gas line is routed from the right side, bend the flex tube 180°.

3/8" M.P.T to 1/2" O.D. Fitting (Factory installed)

Gas Control Valve

10" Flex Tube

(shipped with the fireplace - min. bending radius is 3/4")

Gas Inlet Pressure:

 

Standard Input Pressure

 

 

Natural Gas

7" W.C. (1.74 kPA)

 

 

Propane

13" W.C. (2.73 kPA)

 

 

If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.

The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure.

Travis Industries

4040708

1 0 0 - 0 1 1 6 0

Image 25
Contents If YOU Smell GAS Introduction Important Information 2IntroductionTravis Industries 4040708 0 0 1 1 6 Table of Contents If YOU Smell GAS Safety PrecautionsThis Manual Features Installation Options 6Features and SpecificationsNatural Gas Propane Installation Overview Installation WarningsPacking List Additional Items Required Minimum Framing Dimensions Fireplace Placement RequirementsClearances Raised Fireplaces Corner InstallationsFloor Mounted Fireplaces Hearth RequirementsFacing Over 1 Thick Facing RequirementsTOP View Facing DetailFace Dimensions Installation forModifying the Face Angle for Rectangular Faces Side View Facing and Hearth ExamplesDV Fireplace Combustible Mantels Mantel RequirementsNon-Combustible Mantels Altitude Considerations Vent RequirementsUse of 8 Diameter Pipe Part Numbers for 6-5/8 Diameter VentHorizontal Vent Requirements Vent InstallationRestrictor Position Approved Vent ConfigurationsElbows Measuring Vent LengthsZero or Two 45 Offsets 0feet 5feet 10feet 12max 10 max Feet Horizontal Terminations using 6-5/8 Diameter VentFeet 5feet 10feet 15feet 20feet 25max 40 max Horizontal Terminations using 8 Diameter Vent Termination Requirements see the illustration below Fuel Gas Line RequirementsGas Line Connection Gas Inlet PressureElectrical Connection Re-Attaching the Glass Frame Finalizing the InstallationGlass Frame Removal Spring Pin Installation 8Finalizing the InstallationTop Step 0Finalizing the InstallationFront View Side View Correct Fine Tuning the EMBER-FYRE Burner 2Finalizing the InstallationBefore You Begin Operation3Location of Controls See explanation below Starting The Pilot Flame 4OperationStarting the Fireplace for the First Time Adjusting the Flame HeightTurning the Fireplace On and Off Optional Power Heat Duct Adjusting the Blower Speed6Operation Normal Operating SoundsYearly Service Procedure Maintenance3Maintaining Your Fireplaces Appearance Troubleshooting MaintenanceWhat Turns the Main Burners On and Off How this Fireplace WorksWhat Prevents Gas Buildup Wiring Diagram 0MaintenanceReplacement Parts List Minimum Clearances to Combustibles Safety LabelYears 1 & 2 Coverage Parts & Labor 2Limited 7 Year WarrantyLP Conversion Instructions Burner ReplacementOptional Equipment for qualified installers only Slotted Screwdriver Or T-20 Torx Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions 2Index

36 DV EFIII specifications

The FireplaceXtrordinair 36 DV EFIII is a remarkable direct vent gas fireplace that blends innovative technology with aesthetic appeal, making it an ideal addition to any modern living space. Renowned for its exceptional design and performance, this fireplace provides both warmth and ambience while ensuring efficiency and safety.

One of the standout features of the 36 DV EFIII is its impressive heating capacity. It boasts a maximum output of up to 28,000 BTUs, providing sufficient heat to effectively warm large areas while maintaining energy efficiency. This model is equipped with a powerful fan system that circulates warm air throughout the room, enhancing comfort levels even in colder months.

The FireplaceXtrordinair 36 DV EFIII incorporates advanced technology, including a state-of-the-art electronic ignition system. This feature allows for quick and easy startups without the hassle of traditional matches or lighters. Additionally, the unit is designed with a modulating gas valve, which adjusts the flame height to optimize both heat output and fuel consumption, resulting in impressive energy savings.

The fireplace is also designed with versatility in mind. It offers customizable options, including various decorative media, such as traditional logs, rocks, or contemporary glass, allowing homeowners to create the desired aesthetic that complements their interior design. The 36 DV EFIII is available with multiple front styles and finishes, ensuring it integrates seamlessly with any décor.

Safety is paramount with the FireplaceXtrordinair 36 DV EFIII, featuring a sealed combustion system that draws air from outside the home, reducing the risk of indoor pollution. The direct vent design ensures that all exhaust is expelled outside, providing a clean and safe burning experience.

Another notable characteristic of the 36 DV EFIII is its easy maintenance. The unit is designed for straightforward cleaning, with an accessible glass front that can be easily removed for periodic maintenance. This convenience makes it an attractive option for homeowners looking for a user-friendly fireplace solution.

In conclusion, the FireplaceXtrordinair 36 DV EFIII is a premium direct vent gas fireplace that combines elegance, efficiency, and safety. With its impressive heating capabilities, customizable features, and advanced technology, it stands out as an excellent choice for anyone looking to enhance their home with a high-quality fireplace.