Eclipse Combustion 6500 Illustrated Parts List, Pos Eclipse Qty Description Part Number

Page 44

ILLUSTRATED PARTS

LIST

Pos.

 

 

Eclipse

No.

Qty.

Description

Part Number

 

 

 

 

1

1

Mother Board (6500M)

20315

 

 

 

 

2

1

Relay module circuit board

22494

3

1

Logic module circuit board

22495

 

 

 

 

4

1

Power module circuit board

22496

 

 

 

 

5

1

Sensor circuit board

20314

6

1

183 cm (6ft) cable for remote display

15426

 

 

 

 

6

1

305 cm (10ft) cable for remote display

15426-1

 

 

 

 

7

1

Remote display with keypad

15422

 

 

 

 

Downtimes due to a failure can be kept to a minimum by stocking recommended spares.

1

2

3

4

5

 

 

 

 

6

 

 

 

 

7

View shown with cover removed.

44

Eclipse Bi-Flame v1.8, Instruction Manual 826, 05/03

 

Image 44
Contents Bi-Flame Copyright Disclaimer Notice Liability Warranty About this manual Audience Important Notices Document ConventionsTable of Contents Page Page Introduction Product DescriptionAffectedTerminals SpecificationsIntroduction Dimensions Main ChassisPower Module Modules DescriptionIntroduction Module Description Identification Relay ModuleSensor Module Remote DisplayDIP Switch Selection Introduction DIP Switch Location DIP Switch AccessDIP Switch Settings S2 DIP SwitchesS4 DIP Switches S6 DIP SwitchesFunction Summary Combustion Air Flow Check TerminalMain Fuel Valve Proof-of-Closure Terminal Low Fire Start TerminalRecycle Mode Pilot Test ModeInterrupted or Intermittent Pilot Spark, Pilot Flame and Main Flame SeparationAuxiliary Inputs History LogLast Recycle by AIR=XXXXXX or Last Recycle by FLAME=XXXXXXModulation Contacts Valve Leak Fail Lkout Hhhhmmss Valve Leak Sensing Device Vlsd InterfaceValve Leakage Limits Remote Display UnitRS232 Communication Interfaces RS485 optional Fault AlarmReset AirSystem Faults System Lockout ConditionsSystem Installation Page Remote Reset Remote Display Power must be off when inserting or removing the cableJ6 J3 Wiring Diagram & Connections-Main Chassis Do not ground the shield to terminal GND Sensor InstallationIntroduction Sensor Wiring Flame Rods ScannersScanner Sighting Conditions Test Procedures Introduction Flame Signal Strength Minimum Pilot TestPilot Flame Failure Test Main Flame Faiulre Spark Sighting Test Limits and Interlock TestsIntroduction Maintenance Monthly ChecklistYearly Checklist Troubleshooting Problem Possible Cause Solution Contact Check air filter Check blower rotationRemote Display Messages Bi-Flame Operating Sequence Wait for LO.FIRE Switch AIR ProvenAIR not Proven Lkout Purge AT High FirexxMain Flame on Pilot OFF Automatic ModulationFlame #OX Time = Main # OX FailedPost Purge Main Valve Fail LkoutRemote Display Diagnostic Messages ListedAlphabetically Message Type Explanation Remote Display Diagnostic Messages UNSAFE-FLM-PURGE Valve LeakageValve Leak Fail Watchdog FailAppendix Conversion FactorsMetric to English Metric to MetricIllustrated Parts List Pos Eclipse Qty Description Part Number