Eclipse Combustion 5600 instruction manual Copyright Disclaimer Notice Liability Warranty

Page 2

COPYRIGHT

DISCLAIMER NOTICE

LIABILITY AND

WARRANTY

Copyright 1997 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication is protected by federal regulation and shall not be copied, distributed, transmitted, transcribed or translated into any human or computer language, in any form or by any means, to any third parties,without the express written consent of Eclipse Combustion, Inc., Rockford, Illinois, U.S.A.

In accordance with the manufacturer’s policy of continual product improvement, the product presented in this brochure is subject to change without notice or obligation.

The material in this manual is believed adequate for the intended use of the product. If the product is used for purposes other than those specified herein, confirmation of validity and suitability must be obtained. Eclipse Combustion, Inc. warrants that the product itself does not infringe upon any United States patents. No further warranty is expressed or implied.

We have made every effort to make this manual as accurate and complete as possible. Should you find errors or omissions, please bring them to our attention so that we may correct them. In this way we hope to improve our product documentation for the benefit of our customers. Please send your corrections and comments to our Marketing Communications Manager.

It must be understood that Eclipse Combustion’s liability for its products, whether due to breach of warranty, negligence, strict liability, or otherwise, is limited to the furnishing of burner monitoring system replacement parts and Eclipse Combustion will not be liable for any other injury, loss, damage or expenses, whether direct or consequential, including but not limited to loss of use, income of, or damage to material arising in connection with the sale, installation, use of, inability to use or the repair or replacement of Eclipse Combustion’s products.

Eclipse Combustion, Inc., for a period of one year from shipment, warrants each Veri-Flame burner monitoring system to the original purchaser to be free from defects in material and workmanship under normal use as defined hereafter. Any operation expressly prohibited in this Guide, any adjustment or assembly procedures not recommended or authorized in these instructions, shall void the warranty.

Eclipse Veri-Flame Instruction Manual 818 -2/02

2

Image 2
Contents VeriFlame Single Burner Monitoring System Copyright Disclaimer Notice Liability Warranty About this manual Audience Scope Document ConventionsHOW to GET Help Table of Contents Page LED Status & Conditions for No Purge Models Table Introduction Product DescriptionIntroduction SpecificationsSpecifications Veri-Flame Bases/Purge & No Purge Models DimensionsVeri-Flame Unit/All Models Remote Display Model Number 5602-DBP Veri-Flame/Modulating Model with Base Model NumberRemote Display Model Number 5602-DB DIP Switch Selection Modulation & Purge DIP Switch SettingsDIP Switch Location Main Fuel Valve Closed Switch Terminal Interlocks and Limit Switch Input Terminal Combustion AirIntroduction Standard Features Function SummaryTest Mode Run Mode Seconds Optional Features Status Lights PUSH-BUTTONSystem Installation Ignition Wiring Low Fire Input High Purge Input Remote Reset Remote Display & Power SupplyNo Purge and Purge Wiring Diagrams No Purge Models Typical Connections For All Models Purge and No Purge Bases Modulating BaseSequence Diagrams InputsSensor Installation Sensor Wiring Flame RodsScanners Scanner Sighting Considerations Flame Rod PositionTest Procedures Flame Signal Strength Minimum Pilot TestPilot Flame Failure Test Main Flame FailureTest Spark Sighting Test Limits & Interlock TestsIntroduction Maintenance Maintenance &TroubleshootingMonthly Checklist Yearly Checklist Troubleshooting Problem Possible Cause SolutionLED Status LED Status & Conditions forVeri-Flame Purge Models AIR FailureLED Status & Conditions forVeri-Flame Modulation Models Auto Interlocks ClosedRemote Display Messages Power on Veri-Flame Operating SequenceYES no YES Burner Shutdown AIR Failure Remote Display Diagnostic Messages Xxxxxx Lockout Pilot onInternal Fault Metric to English AppendixConversion Factors Metric to MetricIllustrated Parts List Pos Model Part Category Description Number

5600, VeriFlame Single Burner Monitoring System specifications

The Eclipse Combustion VeriFlame Single Burner Monitoring System, model 5600, represents a significant advancement in the field of combustion management technology. Designed to provide enhanced monitoring and control of burner operations, the VeriFlame system is equipped with state-of-the-art features that ensure optimal efficiency, safety, and performance in a variety of industrial applications.

One of the main features of the VeriFlame 5600 is its advanced flame detection technology, which employs efficient optical sensors to monitor flame presence and stability continuously. This feature enables the system to provide real-time feedback, ensuring that burners operate within specified parameters and respond swiftly to any fluctuations. The system’s intelligent analytics can easily discern between normal operational conditions and potential hazards, enhancing safety and reducing the risk of unsafe operation.

The VeriFlame system is also known for its versatile communication capabilities, featuring multiple connectivity options. The unit can integrate seamlessly with existing plant control systems using industry-standard protocols such as Modbus or Profibus. This interoperability allows for comprehensive data sharing and centralized control of multiple burner systems from a single interface, streamlining operations and improving operator efficiency.

Another notable characteristic of the Eclipse Combustion VeriFlame is its user-friendly interface. The system comes with an intuitive graphical display that provides operators with critical operational data, including flame quality, burner status, and diagnostic information. This straightforward interface facilitates quick decision-making and troubleshooting, minimizing downtime and enhancing the overall operational efficiency of the burner system.

The 5600 model also offers robust diagnostic capabilities, allowing for proactive maintenance and reduced unexpected failures. It features built-in self-check routines and historical data logging, which provide valuable insights into system performance over time. These diagnostic tools empower operators to identify and address potential issues before they escalate, thereby reducing maintenance costs and enhancing the longevity of the burner components.

Moreover, the VeriFlame system is designed with flexibility in mind, accommodating various burner types and fuel sources. This adaptability makes it suitable for use in a wide range of industries, including oil and gas, power generation, and manufacturing.

In conclusion, the Eclipse Combustion VeriFlame Single Burner Monitoring System 5600 stands out due to its advanced flame detection, versatile communication options, user-friendly interface, robust diagnostics, and flexibility. Together, these features make it an essential tool for optimizing combustion processes, enhancing safety, and improving overall operational efficiency in industrial environments.