Eclipse Combustion 5600 instruction manual Purge and No Purge Bases, Modulating Base

Page 22

 

 

 

Figure 5.4

Purge and No Purge Bases

Model Number 5602-10

 

Model Number 5602-10-1

 

 

P3

 

 

 

 

5

3

 

3

6

 

6

4

 

2

P3

 

 

 

 

 

 

S2

V

Jumper

1

4

 

1

P2

 

S1

2

 

 

 

3

6

P2

7

1

 

 

2

P1

 

8

A

 

1

4

 

 

P1

 

 

Jumper

 

 

 

 

 

 

 

Gnd

Gnd

5 6 S2 S1 7 8 A 1 2 V 4 3

 

 

 

 

 

 

NOTE: Ground Terminal

 

 

 

 

nnot present in plastic base.

 

 

Internal Diagram

Purge & No-purge

 

P1

 

 

P1

 

1

5

Fan

1

8

6

 

 

2

 

 

 

 

 

 

Alarm

P1

A

 

 

Fault

Pilot

4

7

P1

P3

 

3

 

 

6

3

 

J1

 

Ign

P3

4

 

 

 

5

 

P3

 

Main

P3

 

V

 

 

3

5

 

 

 

 

 

6

P3

 

 

 

 

 

 

 

 

 

2

P2

 

Supervisor

 

 

 

 

S2

 

 

Flame Signal

Jack

 

P2

 

 

 

Amplifier

 

S1

1

 

 

 

 

 

 

Note: No purge models do not use 6 & 8.

Modulating Base

 

 

 

 

Model Number 5602-40

 

 

 

3

 

 

6

 

1

 

 

 

 

 

1

 

 

 

 

2

 

 

P3

J1

J2

 

 

 

1

 

 

4

 

 

 

 

 

1

 

 

P2

 

 

 

 

 

3

 

 

6

 

 

 

 

 

2

 

 

P1

 

 

 

 

 

1

 

 

4

 

 

 

 

 

 

 

 

 

Jumper

 

Gnd

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8 A D S2 S1 10 11 12 13

Internal Diagram

Modulation Model

 

P1

 

 

P1

 

 

1

5

Fan

 

1

 

8

6

 

 

2

 

 

 

 

 

 

 

 

 

Red

 

 

 

 

 

 

Alarm

P1

 

A

 

 

Fault

Pilot

4

 

 

P1

P3

 

 

7

3

 

Ign

6

 

3

 

 

 

P3

 

 

 

22K

 

Main

5

 

4

 

 

P3

 

 

 

 

P3

 

 

D

22K

 

3

 

5

 

4

 

 

 

 

 

6

P3

 

 

 

 

 

 

2

 

 

 

 

 

 

 

P2

 

Supervisor

 

 

2

2

 

 

 

 

 

 

 

 

 

S2

 

Flame Signal

Jack

 

P2

 

 

Amplifier

 

 

 

S1

1

 

 

 

 

 

 

J2

 

 

 

 

 

 

 

Auto

11

 

 

 

 

2

 

 

 

 

 

 

J2

Low

 

 

J2

 

 

1

12

10

 

 

J2

High

 

4

 

 

3

13

Eclipse Veri-Flame Instruction Manual 818 -2/02

22

Image 22
Contents VeriFlame Single Burner Monitoring System Copyright Disclaimer Notice Liability Warranty About this manual Audience Scope Document ConventionsHOW to GET Help Table of Contents Page LED Status & Conditions for No Purge Models Table Introduction Product DescriptionSpecifications SpecificationsIntroduction Veri-Flame Unit/All Models DimensionsVeri-Flame Bases/Purge & No Purge Models Remote Display Model Number 5602-DB Veri-Flame/Modulating Model with Base Model NumberRemote Display Model Number 5602-DBP DIP Switch Selection Modulation & Purge DIP Switch SettingsDIP Switch Location Main Fuel Valve Closed Switch Terminal Interlocks and Limit Switch Input Terminal Combustion AirIntroduction Standard Features Function SummaryTest Mode Run Mode Seconds Optional Features Status Lights PUSH-BUTTONSystem Installation Ignition Wiring Low Fire Input High Purge Input Remote Reset Remote Display & Power SupplyNo Purge and Purge Wiring Diagrams No Purge Models Typical Connections For All Models Purge and No Purge Bases Modulating BaseSequence Diagrams InputsSensor Installation Sensor Wiring Flame RodsScanners Scanner Sighting Considerations Flame Rod PositionTest Procedures Flame Signal Strength Minimum Pilot TestPilot Flame Failure Test Main Flame FailureTest Spark Sighting Test Limits & Interlock TestsMonthly Checklist Yearly Checklist Maintenance &TroubleshootingIntroduction Maintenance Troubleshooting Problem Possible Cause SolutionLED Status LED Status & Conditions forVeri-Flame Purge Models AIR FailureLED Status & Conditions forVeri-Flame Modulation Models Auto Interlocks ClosedRemote Display Messages Power on Veri-Flame Operating SequenceYES no YES Burner Shutdown AIR Failure Remote Display Diagnostic Messages Xxxxxx Lockout Pilot onInternal Fault Metric to English AppendixConversion Factors Metric to MetricIllustrated Parts List Pos Model Part Category Description Number

5600, VeriFlame Single Burner Monitoring System specifications

The Eclipse Combustion VeriFlame Single Burner Monitoring System, model 5600, represents a significant advancement in the field of combustion management technology. Designed to provide enhanced monitoring and control of burner operations, the VeriFlame system is equipped with state-of-the-art features that ensure optimal efficiency, safety, and performance in a variety of industrial applications.

One of the main features of the VeriFlame 5600 is its advanced flame detection technology, which employs efficient optical sensors to monitor flame presence and stability continuously. This feature enables the system to provide real-time feedback, ensuring that burners operate within specified parameters and respond swiftly to any fluctuations. The system’s intelligent analytics can easily discern between normal operational conditions and potential hazards, enhancing safety and reducing the risk of unsafe operation.

The VeriFlame system is also known for its versatile communication capabilities, featuring multiple connectivity options. The unit can integrate seamlessly with existing plant control systems using industry-standard protocols such as Modbus or Profibus. This interoperability allows for comprehensive data sharing and centralized control of multiple burner systems from a single interface, streamlining operations and improving operator efficiency.

Another notable characteristic of the Eclipse Combustion VeriFlame is its user-friendly interface. The system comes with an intuitive graphical display that provides operators with critical operational data, including flame quality, burner status, and diagnostic information. This straightforward interface facilitates quick decision-making and troubleshooting, minimizing downtime and enhancing the overall operational efficiency of the burner system.

The 5600 model also offers robust diagnostic capabilities, allowing for proactive maintenance and reduced unexpected failures. It features built-in self-check routines and historical data logging, which provide valuable insights into system performance over time. These diagnostic tools empower operators to identify and address potential issues before they escalate, thereby reducing maintenance costs and enhancing the longevity of the burner components.

Moreover, the VeriFlame system is designed with flexibility in mind, accommodating various burner types and fuel sources. This adaptability makes it suitable for use in a wide range of industries, including oil and gas, power generation, and manufacturing.

In conclusion, the Eclipse Combustion VeriFlame Single Burner Monitoring System 5600 stands out due to its advanced flame detection, versatile communication options, user-friendly interface, robust diagnostics, and flexibility. Together, these features make it an essential tool for optimizing combustion processes, enhancing safety, and improving overall operational efficiency in industrial environments.