Beckett 7600 manual Water Flow, Control Wiring

Page 12

Figure 12 - 7600A/B single-zone connections with or without a tankless coil

Water Flow:

AIR

VENT

AIR

SEPARATOR

SK10030

EXPANSION

TANK

COLD

WATER

INLET

Control Wiring:

1.Set “DHWP OFF” (default, see programming section for instructions)

2.Set “C1 on TT” (default, see programming section for instructions)

SK10019

WHITE

TW

TR

RED

LOW VOLTAGE

THERMOSTAT

L2 L1 C1 C2 ZC ZR B1 B2

P1

HEATING

ZONE

NEUTRAL WHITE

 

 

120 VAC

BLACK

WHITE

HOT FIELD/MFR. BLACK

SUPPLIED

 

SERVICE

 

SWITCH

P1

 

 

CIRCULATOR

 

120 VAC

7600A:

120 VAC BURNER OR GAS IGNITION SYSTEM

7600B:

24 VAC GAS IGNITION SYSTEM

12

Image 12
Contents Description / Applications Table of Contents FeaturesTechnical Specifications Electrical Shock HazardElectrical Ratings Environmental RatingsInstallation MountingSensor/Immersion Well Mounting Surface Mounting AquaSmart Models and Cross-Reference Guide Burn, Scald, Explosion, and Equipment Malfunction HazardFrom previous Installing the Temperature Sensor Removing the Control to be Replaced Electrical shock hazardBurn and Scald Hazard Explosion Burn and Scald Hazards 8 hexIn-1 Installation Instructions This is very important for successful control operationWiring Installing the AquaSmart ControlImmersion Well or 2-in-1 Sensor Appliance SurfaceWiring the AquaSmart Control Some Thermostats Are Polarity SensitiveControl Wiring Water Flow7600A/B multi-zone connections Control Wiring Option 2 Circulator-On Delay on All Zones Control Wiring Option 1 7600B only Taco HoneywellControl Wiring Option 2 7600A only Taco HoneywellDHW With Indirect Domestic Hot Water DHW Limit Zone Relay Circulator Control Wiring Option 3 Utilizing a Zone Panel On Next Honewell Taco Temperature High Limit Temperature Low LimitTemperature High Limit Differential Programming Basic FunctionsTemperature Low Limit Differential Changing the Heat Manager SettingsProgramming Additional Options Viewing the Boiler Cycle HistoryChanging the Circulator Settings Key for steps B3 & B5Changing Domestic Hot Water Priority Dhwp Setting Selecting Fahrenheit or Celsius Temperature DisplayChanging Low Water Cut-Off Lwco Setting AquaSmart Boiler Control Manual Control Checkout Procedure AquaSmart OperationSystem Action AquaSmart Response How a Boiler Control Works Troubleshooting Display Boiler Status ModeHeatManager Technology LockoutFinal Checklist ServiceAccessories Page Mounting Template Limited Warranty Information