Beckett 7600 Technical Specifications, Electrical Shock Hazard, Electrical Ratings, Approvals

Page 3

Figure 1 - Getting to know the AquaSmart 7600 Series Control

Electrical Shock Hazard

The AquaSmart control should only be operated with the door attached and securely closed.

Communication Port

 

TW/TR Terminals

 

Sensor Mount

 

 

Touch Pad

 

Sensor Jack

Clamping Screw For Sensor

 

Power Disconnect Switch (Optional)

 

Rotate door until grooves

Pull door up

are aligned

 

Door Removal

 

Technical Specifications

Do Not Use This Control in an Application that is Not

Within the Ratings Listed in This Section. Improper Control Operation May Result.

Temperature Ranges and Differentials

High Limit Setting Range: 100 to 240°F (37 to 115°C)

High Limit Differential Range: 5 to 45°F (2 to 25°C)

Low Limit Setting Range: 100 to 220°F (37 to 104°C)

Low Limit Differential Range: 10 to 45°F (5 to 25°C)

Factory Range Stops available - consult factory

Electrical Ratings

Input Voltage: 120 Vac - 50/60 Hz.

Input Current: 0.1 A + B1 + C1 + ZC

MAX Input Current: 20A (Reduce to 15A if optional power disconnect switch is used)

24 Vac Thermostat Anticipator Current: 0.1 Amp.

Burner Current Rating (B1):

7600A (oil): 7.4 A at 120 Vac FLA; 44.4 A inrush LRA.

7600B (gas): 1.25 A at 24 Vac; 30 VA (total load). Circulator Current Rating (C1): 7.4 A at 120 Vac FLA; 44.4 A inrush LRA.

Zone Control Current Rating (ZC): 7.4 A at 120 Vac FLA; 44.4 A inrush LRA.

Environmental Ratings

Storage Temperature: -40 to +150°F (-40 to +65°C)

Operating Temperature: -4 to +150°F (-20 to +65°C)

7600B at 50 Hz: -4 to +140°F (-20 to +60°C)

Maximum Sensing Element Temperature: 250°F (121°C)

Relative Humidity: 5 to 85% RH, non-condensing and non-crystallizing

Approvals

Underwriters Laboratories Listed to UL353,

UL1998 for U.S. and Canada;

CSA C22.2 No. 24

AquaSmart Boiler Control Manual

3

Image 3
Contents Description / Applications Features Table of ContentsEnvironmental Ratings Technical SpecificationsElectrical Shock Hazard Electrical RatingsInstallation MountingSensor/Immersion Well Mounting Surface Mounting Burn, Scald, Explosion, and Equipment Malfunction Hazard AquaSmart Models and Cross-Reference GuideFrom previous Installing the Temperature Sensor Removing the Control to be Replaced Electrical shock hazardBurn and Scald Hazard 8 hex Explosion Burn and Scald HazardsThis is very important for successful control operation In-1 Installation InstructionsAppliance Surface WiringInstalling the AquaSmart Control Immersion Well or 2-in-1 SensorSome Thermostats Are Polarity Sensitive Wiring the AquaSmart ControlWater Flow Control Wiring7600A/B multi-zone connections Control Wiring Option 2 Circulator-On Delay on All Zones Taco Honeywell Control Wiring Option 1 7600B onlyTaco Honeywell Control Wiring Option 2 7600A onlyDHW With Indirect Domestic Hot Water DHW Limit Zone Relay Circulator Control Wiring Option 3 Utilizing a Zone Panel On Next Honewell Taco Programming Basic Functions Temperature High LimitTemperature Low Limit Temperature High Limit DifferentialViewing the Boiler Cycle History Temperature Low Limit DifferentialChanging the Heat Manager Settings Programming Additional OptionsKey for steps B3 & B5 Changing the Circulator SettingsChanging Domestic Hot Water Priority Dhwp Setting Selecting Fahrenheit or Celsius Temperature DisplayChanging Low Water Cut-Off Lwco Setting AquaSmart Boiler Control Manual Control Checkout Procedure AquaSmart OperationSystem Action AquaSmart Response How a Boiler Control Works Lockout TroubleshootingDisplay Boiler Status Mode HeatManager TechnologyFinal Checklist ServiceAccessories Page Mounting Template Limited Warranty Information